The Instructions For Use for the following: Stryker TRIO+ 4.5 x 45 mm STANDARD POST SCREW Stryker TRIO+ 4.5 x 50 mm STANDARD POST SCREW Stryker TRIO+ 4.5 x 55 mm STANDARD POST SCREW Stryker TRIO+ 5.5 x 45 mm STANDARD POST SCREW Stryker TRIO+ 5.5 x 60 mm STANDARD POST SCREW Manufactured by: STRYKER Spine SAS, Z.I. Marticot - 33610 - Cestas-France +33 (0)5.57.97.06.30 http://www.stryker.com Distributed in the USA by: Stryker Spine, 2 Pearl Ct., Allendale, NJ 07401-1677 USA +1-201-750-8000. The system is intended for posterior, non-cervical pedicle and non-pedicle pedicle fixation of the spine. It is indicated for: degenerative disc disease (DDD), spondylolisthesis, fracture, dislocation, spinal stenosis, scoliosis kyphosis, lordosis, spinal tumor, pseudarthrosis, and failed previous fusion.

Class I - Dangerous

What Should You Do?

  1. Check if you have this product:
    Code information listed in the following format: Manufacturer Part Number/Prodcut Description/Corresponding IFU Part Number/Affected Lot #s are as follows: 48900445/Trio Standard Post Screw 5.5x55mm/#NOLI135B03Rev02/57281 and 57201 48900450/Trio Standard Post Screw 5.5x60mm/#NOLI135B03Rev02/57197 48900455/Trio Standard Post Screw 4.5x45mm/#NOLI135B03Rev02/57198 48900555/Trio Standard Post Screw 4.5x50mm/#NOLI135B03Rev02/56599 48900560/Trio Standard Post Screw 4.5x55mm/#NOLI135B03Rev02/57192
  2. Do not eat it: Even if it looks and smells fine, do not consume this product.
  3. Throw it away or return it: You can return the product to the store for a full refund.
  4. Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
  5. Report problems: Report any issues to the FDA's Safety Reporting Portal.

⚠️ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.

Recall Details

Company:
Stryker Spine
Reason for Recall:
The front cover of Instructions For Use (IFU) #NOLI135B03Rev02 was improperly marked with a "Sterile" logo in the lower right corner. The products these IFUs were packed with are sold as "Non-Sterile" and require sterilization before use in surgery.
Classification:
Class I - Dangerous

Dangerous or defective products that predictably could cause serious health problems or death.

Status:
terminated

Product Information

Full Description:

The Instructions For Use for the following: Stryker TRIO+ 4.5 x 45 mm STANDARD POST SCREW Stryker TRIO+ 4.5 x 50 mm STANDARD POST SCREW Stryker TRIO+ 4.5 x 55 mm STANDARD POST SCREW Stryker TRIO+ 5.5 x 45 mm STANDARD POST SCREW Stryker TRIO+ 5.5 x 60 mm STANDARD POST SCREW Manufactured by: STRYKER Spine SAS, Z.I. Marticot - 33610 - Cestas-France +33 (0)5.57.97.06.30 http://www.stryker.com Distributed in the USA by: Stryker Spine, 2 Pearl Ct., Allendale, NJ 07401-1677 USA +1-201-750-8000. The system is intended for posterior, non-cervical pedicle and non-pedicle pedicle fixation of the spine. It is indicated for: degenerative disc disease (DDD), spondylolisthesis, fracture, dislocation, spinal stenosis, scoliosis kyphosis, lordosis, spinal tumor, pseudarthrosis, and failed previous fusion.

Product Codes/Lot Numbers:

Code information listed in the following format: Manufacturer Part Number/Prodcut Description/Corresponding IFU Part Number/Affected Lot #s are as follows: 48900445/Trio Standard Post Screw 5.5x55mm/#NOLI135B03Rev02/57281 and 57201 48900450/Trio Standard Post Screw 5.5x60mm/#NOLI135B03Rev02/57197 48900455/Trio Standard Post Screw 4.5x45mm/#NOLI135B03Rev02/57198 48900555/Trio Standard Post Screw 4.5x50mm/#NOLI135B03Rev02/56599 48900560/Trio Standard Post Screw 4.5x55mm/#NOLI135B03Rev02/57192

Official Source

Always verify recall information with the official FDA source:

View on FDA.gov

FDA Recall Number: Z-2235-2012