DX-D 600 - DXD Imaging Package Product Usage:Is indicated for use in providing diagnostic quality images to aid the physician with diagnosis. Systems can be used with MUSICA2 image processing to create radiographic images of the skeleton including skull, spinal column and extremities, check abdomen and other both parts.
Class I - DangerousWhat Should You Do?
- Check if you have this product: Serial Nos. A5430000089, A5430000131, A5430000015, A5430000095, A5430000052, A5430000061, A5430000079, A5430000030, A5430000042, A5430000066, A5430000081, A5430000085, A5430000096, A5430000020, A5430000067, A5430000125, A5430000105
- Do not eat it: Even if it looks and smells fine, do not consume this product.
- Throw it away or return it: You can return the product to the store for a full refund.
- Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
- Report problems: Report any issues to the FDA's Safety Reporting Portal.
⚠️ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.
Recall Details
- Company:
- AGFA Healthcare Corp.
- Reason for Recall:
- Some customers reported that while using the DX-D600 in room or exam preparation, the Overhead Tube Crane (OTC) showed increased velocity and uncontrolled longitudinal movement.
- Classification:
- Class I - Dangerous
Dangerous or defective products that predictably could cause serious health problems or death.
- Status:
- terminated
Product Information
Full Description:
DX-D 600 - DXD Imaging Package Product Usage:Is indicated for use in providing diagnostic quality images to aid the physician with diagnosis. Systems can be used with MUSICA2 image processing to create radiographic images of the skeleton including skull, spinal column and extremities, check abdomen and other both parts.
Product Codes/Lot Numbers:
Serial Nos. A5430000089, A5430000131, A5430000015, A5430000095, A5430000052, A5430000061, A5430000079, A5430000030, A5430000042, A5430000066, A5430000081, A5430000085, A5430000096, A5430000020, A5430000067, A5430000125, A5430000105
Distribution:
Distributed in: US, GA, IN, KS, KY, MA, NJ, SC, VA, DC
Official Source
Always verify recall information with the official FDA source:
View on FDA.govFDA Recall Number: Z-2175-2014
Related Recalls
Agfa Healthcare NX 3.0.8950 Imaging Processing Software
AGFA Healthcare
A customer reported that when using an NX workstation with software version NX 3.0.8950 software and selecting the affected patient/exam from closed exams, initially the wrong image was linked to the exam and appeared. After a short time the wrong image was replaced by the correct image, however the wrong image was used for transmitting to PACS.
A customer experienced when using IMPAX CV Reporting software, specifically, when building a NIV report, the NIV Cardio report was showing incorrect findings for Aneurysm.
DX-D600 - DXD Imaging Package
AGFA Healthcare
One of the dent markers from the DX-D600 dropped down from the overhead rail.