Epix latis GRASPER, 5 mm x 35 cm, REF C4130, Qty: 10, Sterile R, CE, Rx ONLY, UDI: (01)00607915110147
Class I - DangerousWhat Should You Do?
- Check if you have this product: Batch: 1364578/Expiration Date: July 28, 2022; Batch: 1366453/Expiration Date: August 13, 2022; Batch: 1371249/Expiration Date: October 3, 2022; Batch: 1373050/Expiration Date: October 23, 2022; Batch: 1373248/Expiration Date: November 4, 2022; Batch: 1373249/Expiration Date: November 11, 2022; Batch: 1373255/Expiration Date: November 18, 2022; Batch: 1373260/Expiration Date: November 19, 2022; Batch; 1373261/Expiration Date: November 24, 2022; Batch: 1373262/Expiration Date: December 2, 2022; Batch: 1373263/Expiration Date: December 5, 2022; Batch: 1377363/Expiration Date: December 11, 2022; Batch: 1377364/Expiration Date: December 17, 2022
- Do not eat it: Even if it looks and smells fine, do not consume this product.
- Throw it away or return it: You can return the product to the store for a full refund.
- Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
- Report problems: Report any issues to the FDA's Safety Reporting Portal.
β οΈ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.
Recall Details
- Company:
- Applied Medical Resources Corp
- Reason for Recall:
- There may be a slightly protruding rivet on the distal end of the laparoscopic grasper which has the potential for tissue to catch on it during use and lead to tissue damage.
- Classification:
- Class I - Dangerous
Dangerous or defective products that predictably could cause serious health problems or death.
- Status:
- terminated
Product Information
Full Description:
Epix latis GRASPER, 5 mm x 35 cm, REF C4130, Qty: 10, Sterile R, CE, Rx ONLY, UDI: (01)00607915110147
Product Codes/Lot Numbers:
Batch: 1364578/Expiration Date: July 28, 2022; Batch: 1366453/Expiration Date: August 13, 2022; Batch: 1371249/Expiration Date: October 3, 2022; Batch: 1373050/Expiration Date: October 23, 2022; Batch: 1373248/Expiration Date: November 4, 2022; Batch: 1373249/Expiration Date: November 11, 2022; Batch: 1373255/Expiration Date: November 18, 2022; Batch: 1373260/Expiration Date: November 19, 2022; Batch; 1373261/Expiration Date: November 24, 2022; Batch: 1373262/Expiration Date: December 2, 2022; Batch: 1373263/Expiration Date: December 5, 2022; Batch: 1377363/Expiration Date: December 11, 2022; Batch: 1377364/Expiration Date: December 17, 2022
Distribution:
Nationwide distribution
Official Source
Always verify recall information with the official FDA source:
View on FDA.govFDA Recall Number: Z-2158-2020
Related Recalls
Kii Low Profile, Bladed Dual Pack , Qty. 1 5x55mm REF: CTB23
Applied Medical Resources
There is the potential for extended length of the blade obturator after assembly into the cannula and seal housing.
Epix Universal Clip Applier, REF: CA500, STERILEEO
Applied Medical Resources
Their is the potential that Universal Clip applier may not load clip after the trigger is actuated.
Their is the potential that Universal Clip applier may not load clip after the trigger is actuated.