12C
Class I - DangerousWhat Should You Do?
- Check if you have this product: Code/Serial Numbers: PAT.000, PAT.003, PAT.006, PAT.107, PAT.108, PAT.109, PAT.110, PAT.111, PAT.112, PAT.113, PAT.114, PAT.115, SAT.116, SAT.117, SAT.119, SAT.120, SAT.122, SAT.123, SAT.126, SBF.101
- Do not eat it: Even if it looks and smells fine, do not consume this product.
- Throw it away or return it: You can return the product to the store for a full refund.
- Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
- Report problems: Report any issues to the FDA's Safety Reporting Portal.
⚠️ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.
Recall Details
- Company:
- Ion Beam Applications S.A.
- Reason for Recall:
- IBA is initiating this recall to notify its customers that the use of non-IBA accessories and/or third party equipment or unauthorized modifications to an IBA medical device may pose a safety risk.
- Classification:
- Class I - Dangerous
Dangerous or defective products that predictably could cause serious health problems or death.
- Status:
- terminated
Product Information
Full Description:
12C
Product Codes/Lot Numbers:
Code/Serial Numbers: PAT.000, PAT.003, PAT.006, PAT.107, PAT.108, PAT.109, PAT.110, PAT.111, PAT.112, PAT.113, PAT.114, PAT.115, SAT.116, SAT.117, SAT.119, SAT.120, SAT.122, SAT.123, SAT.126, SBF.101
Official Source
Always verify recall information with the official FDA source:
View on FDA.govFDA Recall Number: Z-2138-2018
Related Recalls
IBA Proton Therapy System - PROTEUS 235 ProteusPLUS and ProteusONE Software versions: PTS-8 versions, PTS-10 versions, PTS-11 versions, and PTS-12 versions
Ion Beam Applications S.A.
Safety Parameters Verification Mechanisms can be deactivated in clinical runtime
IBA Proton Therapy System - PROTEUS 235- Designed to produce and deliver a proton beam for the treatment of patients with localized tumors and other conditions susceptible to treatment by radiation
Ion Beam Applications S.A.
Temporary deactivation of collision detection for Forte Robotic Patient Positioning System occasionally experiences issues
IBA Proton Therapy System - PROTEUS 235 - Designed to produce and deliver a proton beam for the treatment of patients with localized tumors and other conditions susceptible to treatment by radiation.
Ion Beam Applications S.A.
Irradiation is not interrupted when some C230 Accelerator Control Unit critical parameters are outside of the defined tolerances