90597002009 Articular Surface CR ART SURF 12/PURPLE 09MM, Rx, Sterile; 90597002010 Articular Surface CR ART SURF 12/PURPLE 10MM, Rx, Sterile; 90597002012 Articular Surface CR ART SURF 12/PURPLE 12MM, Rx, Sterile; 90597002014 Articular Surface CR ART SURF 12/PURPLE 14MM, Rx, Sterile; 90597002017 Articular Surface CR ART SURF 12/PURPLE 17MM, Rx, Sterile; 90597002020 Articular Surface CR ART SURF 12/PURPLE 20MM, Rx, Sterile; Used in total knee arthroplasty and indicated for patients with severe pain.
Class I - DangerousWhat Should You Do?
- Check if you have this product: all codes
- Do not eat it: Even if it looks and smells fine, do not consume this product.
- Throw it away or return it: You can return the product to the store for a full refund.
- Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
- Report problems: Report any issues to the FDA's Safety Reporting Portal.
ā ļø Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.
Recall Details
- Company:
- Zimmer, Inc.
- Reason for Recall:
- Surgeons are implanting components of the NexGen Cruciate Retaining (CR) Complete Knee System in combinations that are not approved (micro with standard). Includes CR Micro Femurs, Articular Surface, Patellae, instruments and provisionals combined with standard components. A March 2012 recall reiterated the proper combination labeling, but the mis match problem continues. Zimmer is removing the d
- Classification:
- Class I - Dangerous
Dangerous or defective products that predictably could cause serious health problems or death.
- Status:
- terminated
Product Information
Full Description:
90597002009 Articular Surface CR ART SURF 12/PURPLE 09MM, Rx, Sterile; 90597002010 Articular Surface CR ART SURF 12/PURPLE 10MM, Rx, Sterile; 90597002012 Articular Surface CR ART SURF 12/PURPLE 12MM, Rx, Sterile; 90597002014 Articular Surface CR ART SURF 12/PURPLE 14MM, Rx, Sterile; 90597002017 Articular Surface CR ART SURF 12/PURPLE 17MM, Rx, Sterile; 90597002020 Articular Surface CR ART SURF 12/PURPLE 20MM, Rx, Sterile; Used in total knee arthroplasty and indicated for patients with severe pain.
Product Codes/Lot Numbers:
all codes
Official Source
Always verify recall information with the official FDA source:
View on FDA.govFDA Recall Number: Z-2019-2013