CIVCO VirtuTRAX Instrument Navigator, Reusable non-sterile general purpose driveBAY, trakSTAR, electromagnetic sensor (8mm) with VirtuTRAX Instrument navigator and (8.9 tapered to 1.3 x 147cm) telescopically-folded CIV-Flex sensor covers (5), Ref. 610-1080. The firm name on the label is CIVCO, Kalona, IA. The kit contains sensor component part number 410-240. The general purpose sensor within the kit is intended to provide physicians with tools for electromagnetic tracking of instruments with respect to image data. The sensors are designed to attach to custom reusable tracking bracket for leading transducers and other medical devices
Class I - DangerousWhat Should You Do?
- Check if you have this product: Lot numbers M493010, M493220, M708150, M710060, M783360, M803040, M803520, M808870, M823690, M832260, M840620, M848450, M855680, and M871810.
- Do not eat it: Even if it looks and smells fine, do not consume this product.
- Throw it away or return it: You can return the product to the store for a full refund.
- Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
- Report problems: Report any issues to the FDA's Safety Reporting Portal.
⚠️ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.
Recall Details
- Company:
- Civco Medical Instruments Inc
- Reason for Recall:
- The general purpose electromagnetic sensor was incorrectly calibrated causing potential variability in the projected position of the needle path with the ultrasound device.
- Classification:
- Class I - Dangerous
Dangerous or defective products that predictably could cause serious health problems or death.
- Status:
- terminated
Product Information
Full Description:
CIVCO VirtuTRAX Instrument Navigator, Reusable non-sterile general purpose driveBAY, trakSTAR, electromagnetic sensor (8mm) with VirtuTRAX Instrument navigator and (8.9 tapered to 1.3 x 147cm) telescopically-folded CIV-Flex sensor covers (5), Ref. 610-1080. The firm name on the label is CIVCO, Kalona, IA. The kit contains sensor component part number 410-240. The general purpose sensor within the kit is intended to provide physicians with tools for electromagnetic tracking of instruments with respect to image data. The sensors are designed to attach to custom reusable tracking bracket for leading transducers and other medical devices
Product Codes/Lot Numbers:
Lot numbers M493010, M493220, M708150, M710060, M783360, M803040, M803520, M808870, M823690, M832260, M840620, M848450, M855680, and M871810.
Distribution:
Distributed in: WI, CA, MA, IN, WA, NJ
Official Source
Always verify recall information with the official FDA source:
View on FDA.govFDA Recall Number: Z-1956-2012
Related Recalls
Leaks were detected in the recalled lot which may compromise the sterility of the product.
A pinhole leak identified in the packaging of the recalled product potentially could compromise the sterility of the product.
Scales adhered to the product may be misaligned from the zero reference such that one side will not match the other.