5.5mm Diameter x 500mm CoCr Straight Rod, Model number X077-0420. The product is packaged in plastic bags with one piece per bag. Product Usage: The 5.5mm dia. X 500 mm CoCr Straight Rod is an accessory to the Fortex Pedicle Screw System. It is a straight rod connected between two or more pedicle screws to create a pedicle screw construct. Indications for Use: The Fortex Pedicle Screw System is indicated for the treatment of severe spondylolisthesis (Grade 3 and 4) of the L5-S1 vertebra in skeletally mature patients receiving fusion by autogenous bone graft having implants attached to the lumbar and sacral spine (L3 to sacrum) with removal of the implants after the attainment of a solid fusion. In addition, the system is intended to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of the thoracic, lumbar and sacral spine: degenerative spondylolisthesis with objective evidence of neurological impairment, fracture, dislocation, scoliosis, kyphosis, spinal tumor, and failed previous fusion (pseudarthrosis).

Class I - Dangerous

What Should You Do?

  1. Check if you have this product:
    Part number X077-0420, lot number 041218
  2. Do not eat it: Even if it looks and smells fine, do not consume this product.
  3. Throw it away or return it: You can return the product to the store for a full refund.
  4. Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
  5. Report problems: Report any issues to the FDA's Safety Reporting Portal.

⚠️ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.

Recall Details

Company:
XTANT MEDICAL INC
Reason for Recall:
The material type on the label may incorrectly state Ti6Al-4V ELI. The rods are composed of Cobalt Chromium.
Classification:
Class I - Dangerous

Dangerous or defective products that predictably could cause serious health problems or death.

Status:
terminated

Product Information

Full Description:

5.5mm Diameter x 500mm CoCr Straight Rod, Model number X077-0420. The product is packaged in plastic bags with one piece per bag. Product Usage: The 5.5mm dia. X 500 mm CoCr Straight Rod is an accessory to the Fortex Pedicle Screw System. It is a straight rod connected between two or more pedicle screws to create a pedicle screw construct. Indications for Use: The Fortex Pedicle Screw System is indicated for the treatment of severe spondylolisthesis (Grade 3 and 4) of the L5-S1 vertebra in skeletally mature patients receiving fusion by autogenous bone graft having implants attached to the lumbar and sacral spine (L3 to sacrum) with removal of the implants after the attainment of a solid fusion. In addition, the system is intended to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of the thoracic, lumbar and sacral spine: degenerative spondylolisthesis with objective evidence of neurological impairment, fracture, dislocation, scoliosis, kyphosis, spinal tumor, and failed previous fusion (pseudarthrosis).

Product Codes/Lot Numbers:

Part number X077-0420, lot number 041218

Official Source

Always verify recall information with the official FDA source:

View on FDA.gov

FDA Recall Number: Z-1884-2017

Related Recalls

XTANT Medical, ## mm x ## mm x # mm x # ,Lordotic/Packaged InTice - C, Sterile R, Single Use Only, for the following Reference numbers/ Primary DI Number/Material Grade on Label: Ref: X098-0106-STR DI Number: M697X0980106STR1 Mat.: CP Ti Grade 3, Ref: X098-0107-STR DI Number: M697X0980107STR1 Mat.: CP Ti Grade 4, Ref: X098-0108-STR DI Number: M697X0980108STR1 Mat.: CP Ti Grade 5, Ref: X098-0109-STR DI Number: M697X0980109STR1 Mat.: CP Ti Grade 6, Ref: X098-0110-STR DI Number: M697X0980110STR1 Mat.: CP Ti Grade 7, Ref: X098-0111-STR DI Number: M697X0980111STR1 Mat.: CP Ti Grade 8, Ref: X098-0112-STR DI Number: M697X0980112STR1 Mat.: CP Ti Grade 9, Ref: X098-0205-STR DI Number: M697X0980205STR1 Mat.: CP Ti Grade 10, Ref: X098-0206-STR DI Number: M697X0980206STR1 Mat.: CP Ti Grade 11, Ref: X098-0207-STR DI Number: M697X0980207STR1 Mat.: CP Ti Grade 12, Ref: X098-0208-STR DI Number: M697X0980208STR1 Mat.: CP Ti Grade 13, Ref: X098-0209-STR DI Number: M697X0980209STR1 Mat.: CP Ti Grade 14, Ref: X098-0210-STR DI Number: M697X0980210STR1 Mat.: CP Ti Grade 15, Ref: X098-0211-STR DI Number: M697X0980211STR1 Mat.: CP Ti Grade 16, Ref: X098-0212-STR DI Number: M697X0980212STR1 Mat.: CP Ti Grade 17, Ref: X098-0305-STR DI Number: M697X0980305STR1 Mat.: CP Ti Grade 18, Ref: X098-0306-STR DI Number: M697X0980306STR1 Mat.: CP Ti Grade 19, Ref: X098-0307-STR DI Number: M697X0980307STR1 Mat.: CP Ti Grade 20, Ref: X098-0308-STR DI Number: M697X0980308STR1 Mat.: CP Ti Grade 21, Ref: X098-0309-STR DI Number: M697X0980309STR1 Mat.: CP Ti Grade 22, Ref: X098-0310-STR DI Number: M697X0980310STR1 Mat.: CP Ti Grade 23, Ref: X098-0311-STR DI Number: M697X0980311STR1 Mat.: CP Ti Grade 24, Ref: X098-0312-STR DI Number: M697X0980312STR1 Mat.: CP Ti Grade 25

XTANT Medical

Class I - Dangerous

Cervical Implants contain a label that incorrectly identifies the grade of titanium used.

Sep 30, 2020 Other Medical Devices View Details →