ExacTrac 5.5, an Image Processing System used for patient positioning for radiation therapy or radiosurgery.
Class I - DangerousWhat Should You Do?
- Check if you have this product: ExacTrac software version 5.5.5 is included in the following model / catalog numbers: 1) 20818B ET SOFTWARE 5.5.5; 2) 20820 ET SOFTWARE UPDATE 5.0 TO 5.5; 3) 49905D EXACTRAC COMPLETE SYSTEM UPG 3.X TO 5.5; 4) 49908C EXACTRAC SOFTWARE UPGRADE 3.X TO 5.5; 5) 49909A EXACTRAC SOFTWARE UPGRADE 4.X TO 5.5; 6) 49918 ET SOFTWARE UPDATE 5.5.X TO 5.5.5; 7) 49919 ET SOFTWARE UPDATE 5.0.X TO 5.5.5; 8) 49660A ET INFRARED SOFTWARE 5.5.5; 9) 49961 ET DATA PREP/REVIEW SYSTEM; 10) 49986 ET SYSTEM UPGRADE 3.X TO 5.5 NEW VAULT; 11) 49987 ET SYSTEM UPGRADE 4.X TO 5.5 NEW VAULT; 12) 49988 ET SYSTEM UPGRADE 4.X TO 5.5 SAME VAULT; 13) 49989 ET SYSTEM UPGRADE 5.0 TO 5.5 NEW VAULT; 14) 49990 ET SYSTEM UPGRADE 5.0 TO 5.5 SAME VAULT; 15) 49991 ET SYSTEM UPGRADE 5.5 TO 5.5 NEW VAULT
- Do not eat it: Even if it looks and smells fine, do not consume this product.
- Throw it away or return it: You can return the product to the store for a full refund.
- Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
- Report problems: Report any issues to the FDA's Safety Reporting Portal.
⚠️ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.
Recall Details
- Company:
- Brainlab AG
- Reason for Recall:
- When using a specific plan update workflow in combination with a non-Brainlab treatment planning system (TPS), there is a possibility in ExacTrac 5.5.5 to generate an unintended blend of two initially separate plans of the same patient.
- Classification:
- Class I - Dangerous
Dangerous or defective products that predictably could cause serious health problems or death.
- Status:
- terminated
Product Information
Full Description:
ExacTrac 5.5, an Image Processing System used for patient positioning for radiation therapy or radiosurgery.
Product Codes/Lot Numbers:
ExacTrac software version 5.5.5 is included in the following model / catalog numbers: 1) 20818B ET SOFTWARE 5.5.5; 2) 20820 ET SOFTWARE UPDATE 5.0 TO 5.5; 3) 49905D EXACTRAC COMPLETE SYSTEM UPG 3.X TO 5.5; 4) 49908C EXACTRAC SOFTWARE UPGRADE 3.X TO 5.5; 5) 49909A EXACTRAC SOFTWARE UPGRADE 4.X TO 5.5; 6) 49918 ET SOFTWARE UPDATE 5.5.X TO 5.5.5; 7) 49919 ET SOFTWARE UPDATE 5.0.X TO 5.5.5; 8) 49660A ET INFRARED SOFTWARE 5.5.5; 9) 49961 ET DATA PREP/REVIEW SYSTEM; 10) 49986 ET SYSTEM UPGRADE 3.X TO 5.5 NEW VAULT; 11) 49987 ET SYSTEM UPGRADE 4.X TO 5.5 NEW VAULT; 12) 49988 ET SYSTEM UPGRADE 4.X TO 5.5 SAME VAULT; 13) 49989 ET SYSTEM UPGRADE 5.0 TO 5.5 NEW VAULT; 14) 49990 ET SYSTEM UPGRADE 5.0 TO 5.5 SAME VAULT; 15) 49991 ET SYSTEM UPGRADE 5.5 TO 5.5 NEW VAULT
Official Source
Always verify recall information with the official FDA source:
View on FDA.govFDA Recall Number: Z-1707-2014
Related Recalls
Under certain circumstances, it can occur that patient records from unrelated individuals are automatically merged into one patient record without user notification.
Cirq Arm System 2.0
Brainlab AG
Risk of mechanical instability due to potential manufacturing error of the device
Deep Inspiration Breath Hold (DIBH) functionality may not work as specified when based on a standard-workflow Treatment Template