HLS/HIT Set Advanced with Bioline and/or Softline Coating Console Product Usage: HLS/HIT Set Advanced: The CARDIO HELP System in configuration with the HLS/HIT Set Advanced is intended to be used within the hospital environment and outside the hospital environment (for periods up to six hours), e.g. for intra- and inter-hospital transport. Due to its system combination of integrated oxygenator and centrifugal pump, the HLS Set Advanced is suitable for both extracorporeal pulmonary support and cardiovascular support, and for simultaneous cardiovascular and pulmonary support.

Class I - Dangerous

What Should You Do?

  1. Check if you have this product:
    Part numbers BEQ-HLS 5050, 70105,2797, BEQ-HLS 7050, 70105.2794, and BO-HLS 7050, 70105.2786
  2. Do not eat it: Even if it looks and smells fine, do not consume this product.
  3. Throw it away or return it: You can return the product to the store for a full refund.
  4. Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
  5. Report problems: Report any issues to the FDA's Safety Reporting Portal.

⚠️ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.

Recall Details

Company:
Maquet Cardiovascular Us Sales, Llc
Reason for Recall:
A potential issue was detected that could result in blood leakage from the gas outlet port in all lots of Quadrox-iD Adult Diffusion Membrane Oxygenator with Bioline and Softline Coatings, Custom Tubing Packs and Diffusion Membrane HLS Set Advanced and HIT Set Advanced Models.
Classification:
Class I - Dangerous

Dangerous or defective products that predictably could cause serious health problems or death.

Status:
terminated

Product Information

Full Description:

HLS/HIT Set Advanced with Bioline and/or Softline Coating Console Product Usage: HLS/HIT Set Advanced: The CARDIO HELP System in configuration with the HLS/HIT Set Advanced is intended to be used within the hospital environment and outside the hospital environment (for periods up to six hours), e.g. for intra- and inter-hospital transport. Due to its system combination of integrated oxygenator and centrifugal pump, the HLS Set Advanced is suitable for both extracorporeal pulmonary support and cardiovascular support, and for simultaneous cardiovascular and pulmonary support.

Product Codes/Lot Numbers:

Part numbers BEQ-HLS 5050, 70105,2797, BEQ-HLS 7050, 70105.2794, and BO-HLS 7050, 70105.2786

Official Source

Always verify recall information with the official FDA source:

View on FDA.gov

FDA Recall Number: Z-1690-2015

Related Recalls

The Printed Circuit Board Assembly (PCBA) are not in compliance with the IEC standard (60601 1, third edition). The BMU 40 units affected by this recall were designed with a short creepage distance of 1.8 mm between the two distinct and proximal areas on the printed circuit board (PCB) where as the standard requires a creepage distance of 4 mm.