Capio SLIM Suture Capturing Device, Model #M0068318250. Intended for use in general suturing applications during open surgery to assist in the placement of suture material in tissues at the operative site.

Class I - Dangerous

What Should You Do?

  1. Check if you have this product:
    UDI:08714729842224. Batch numbers: 17781206 19335463 20312941 17782808 19435078 20423794 17790316 19568158 20453711 17792469 19573475 20453712 17986321 19701151 20475301 17991696 19711511 20484084 18106407 19833973 20484085 18110253 19858683 20532136 18213570 19858950 20628943 18304052 19882066 20633409 18384108 19882067 20637817 18407974 19887279 20693087 18420687 19942844 20697608 18492494 19959781 20838671 18494737 19963492 20838674 18620481 19993297 20838675 18740238 20000796 20838676 18792184 20001160 20902944 18855259 20001161 20968694 18922488 20006757 21065530 18925301 20009446 21135395 19027722 20017944 21166978 19138109 20202691 21168424 19173080 20203473 21168425 19243603 20305797 21258657 19243604 20305799 21362103 19335462 20305920 21386335
  2. Do not eat it: Even if it looks and smells fine, do not consume this product.
  3. Throw it away or return it: You can return the product to the store for a full refund.
  4. Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
  5. Report problems: Report any issues to the FDA's Safety Reporting Portal.

⚠️ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.

Recall Details

Company:
Boston Scientific Corporation
Reason for Recall:
Potential for Capio sutures to break and /or detach.
Classification:
Class I - Dangerous

Dangerous or defective products that predictably could cause serious health problems or death.

Status:
terminated

Product Information

Full Description:

Capio SLIM Suture Capturing Device, Model #M0068318250. Intended for use in general suturing applications during open surgery to assist in the placement of suture material in tissues at the operative site.

Product Codes/Lot Numbers:

UDI:08714729842224. Batch numbers: 17781206 19335463 20312941 17782808 19435078 20423794 17790316 19568158 20453711 17792469 19573475 20453712 17986321 19701151 20475301 17991696 19711511 20484084 18106407 19833973 20484085 18110253 19858683 20532136 18213570 19858950 20628943 18304052 19882066 20633409 18384108 19882067 20637817 18407974 19887279 20693087 18420687 19942844 20697608 18492494 19959781 20838671 18494737 19963492 20838674 18620481 19993297 20838675 18740238 20000796 20838676 18792184 20001160 20902944 18855259 20001161 20968694 18922488 20006757 21065530 18925301 20009446 21135395 19027722 20017944 21166978 19138109 20202691 21168424 19173080 20203473 21168425 19243603 20305797 21258657 19243604 20305799 21362103 19335462 20305920 21386335

Distribution:

Distributed in: US

Official Source

Always verify recall information with the official FDA source:

View on FDA.gov

FDA Recall Number: Z-1616-2018

Related Recalls

Class I - Dangerous

Software to enhance Safety Architecture is available and designed to prevent initiation of Safety Mode in an ambulatory setting due to a high battery impedance state for the ACCOLADE family of devices which includes ACCOLADE, PROPONENT, ESSENTIO, and ALTRUA 2 dual chamber (DR) standard life (SL) and DR extended life (EL) pacemakers; and VISIONIST and VALITUDE cardiac resynchronization therapy pacemakers (CRT-Ps).

Aug 20, 2025 Implants & Prosthetics View Details →
Class I - Dangerous

Software to enhance Safety Architecture is available and designed to prevent initiation of Safety Mode in an ambulatory setting due to a high battery impedance state for the ACCOLADE family of devices which includes ACCOLADE, PROPONENT, ESSENTIO, and ALTRUA 2 dual chamber (DR) standard life (SL) and DR extended life (EL) pacemakers; and VISIONIST and VALITUDE cardiac resynchronization therapy pacemakers (CRT-Ps).

Aug 20, 2025 Implants & Prosthetics View Details →
Class I - Dangerous

Software to enhance Safety Architecture is available and designed to prevent initiation of Safety Mode in an ambulatory setting due to a high battery impedance state for the ACCOLADE family of devices which includes ACCOLADE, PROPONENT, ESSENTIO, and ALTRUA 2 dual chamber (DR) standard life (SL) and DR extended life (EL) pacemakers; and VISIONIST and VALITUDE cardiac resynchronization therapy pacemakers (CRT-Ps).

Aug 20, 2025 Other Medical Devices View Details →