Zimmer Biomet Alvarado Knee Holder Base Plate Assembly and Foot Piece, & Alvarado II Base Plate and Foot Piece: Alvarado Foot Piece: Item Number: 00-1320-010-00 Alvarado Knee Holder Base Plate Assembly: Item Number: 00-1320-011-00 Alvarado II Foot Piece: Item Number: 00-1320-210-00 Alvarado II Base Plate: Item Number: 00-1320-211-00 Product Usage: This device is designed to hold the patient s knee in the selected position during surgery. The Alvarado Knee Holder includes a Base Plate assembly with two rows of slotted hooks. These rows extend upward from the base plate for a sufficient length to provide adequate selective adjustment. A Foot Piece is mounted on an alignment rod that is pivotally engaged into the hook portion of the slots.
Class I - DangerousWhat Should You Do?
- Check if you have this product: All lot codes
- Do not eat it: Even if it looks and smells fine, do not consume this product.
- Throw it away or return it: You can return the product to the store for a full refund.
- Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
- Report problems: Report any issues to the FDA's Safety Reporting Portal.
⚠️ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.
Recall Details
- Company:
- Zimmer Surgical Inc
- Reason for Recall:
- Foreign Material in the Alvarado Knee Holder Base Plate Assembly and Foot Piece and Alvarado II Base Plate and Foot Piece due to potentially inadequate cleaning procedures
- Classification:
- Class I - Dangerous
Dangerous or defective products that predictably could cause serious health problems or death.
- Status:
- terminated
Product Information
Full Description:
Zimmer Biomet Alvarado Knee Holder Base Plate Assembly and Foot Piece, & Alvarado II Base Plate and Foot Piece: Alvarado Foot Piece: Item Number: 00-1320-010-00 Alvarado Knee Holder Base Plate Assembly: Item Number: 00-1320-011-00 Alvarado II Foot Piece: Item Number: 00-1320-210-00 Alvarado II Base Plate: Item Number: 00-1320-211-00 Product Usage: This device is designed to hold the patient s knee in the selected position during surgery. The Alvarado Knee Holder includes a Base Plate assembly with two rows of slotted hooks. These rows extend upward from the base plate for a sufficient length to provide adequate selective adjustment. A Foot Piece is mounted on an alignment rod that is pivotally engaged into the hook portion of the slots.
Product Codes/Lot Numbers:
All lot codes
Official Source
Always verify recall information with the official FDA source:
View on FDA.govFDA Recall Number: Z-1494-2019
Related Recalls
3:1 Dermacarrier, Model Number 00219501300, skin graft carrier
Zimmer Surgical
Due to manufacturing issue, the product is labeled as 3:1 ratio, but the ridge pattern is a 1.5:1 ratio. The problem may lead to minor tissue damage or additional unplanned graft if deemed necessary.
Skin grafts thin and non-uniform when using the affected blades. The issue would be identified at the time of use and may result in the need for additional harvests to adequately cover the area
When inflating/deflating a single bladder, both bladders could potentially inflate/deflate due to a leak between the bladders.