2D Perfusion, release R1.0.x, R1.1.x, R1.2, and R1.2.1

Class I - Dangerous

What Should You Do?

  1. Check if you have this product:
    UDI: (01)00884838059276 2D Perfusion with Allura Xper or Azurion model number: 722003, 722006, 722008, 722010, 722012, 722013, 722020, 722023, 722026, 722027 722028, 722029, 722035, 722038, 722039, 722058, 722059, 722064, 722067 722068, 722078, 722079, 722223, 722224, 722225, 722226, 722227 and 722228. Software License Keys: 459801071511 sw key 2D Perfusion (IW) 459800240601 sw key 2D Perfusion (XV)
  2. Do not eat it: Even if it looks and smells fine, do not consume this product.
  3. Throw it away or return it: You can return the product to the store for a full refund.
  4. Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
  5. Report problems: Report any issues to the FDA's Safety Reporting Portal.

⚠️ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.

Recall Details

Company:
PHILIPS MEDICAL SYSTEMS NEDERLAND B.V.
Reason for Recall:
There are technical issues related to signal generation and processing, which can lead to inaccurate presentations.
Classification:
Class I - Dangerous

Dangerous or defective products that predictably could cause serious health problems or death.

Status:
ongoing

Product Information

Full Description:

2D Perfusion, release R1.0.x, R1.1.x, R1.2, and R1.2.1

Product Codes/Lot Numbers:

UDI: (01)00884838059276 2D Perfusion with Allura Xper or Azurion model number: 722003, 722006, 722008, 722010, 722012, 722013, 722020, 722023, 722026, 722027 722028, 722029, 722035, 722038, 722039, 722058, 722059, 722064, 722067 722068, 722078, 722079, 722223, 722224, 722225, 722226, 722227 and 722228. Software License Keys: 459801071511 sw key 2D Perfusion (IW) 459800240601 sw key 2D Perfusion (XV)

Official Source

Always verify recall information with the official FDA source:

View on FDA.gov

FDA Recall Number: Z-1417-2023

Related Recalls

The motorized longitudinal movement of the FlexArm stand may be inconsistent (not smooth) and eventually may become unavailable. This issue is due to grease leakage from the bearings and/or anti-corrosion oil applied on the bearings, because of which the lubrication on the ceiling rail may be excessive, reducing the friction between the rails and the friction wheel. Expansion to add additional model.

Oct 2, 2025 Other Medical Devices Nationwide View Details →

The BIOS battery may deplete faster than initially anticipated during the design phase. When the battery is depleted, the start-up process of the system will be halted, and the system will not start. No user messages are shown before the battery is low on power or depleted.

Sep 3, 2025 Other Medical Devices Nationwide View Details →