Biolox Delta Femoral Head - The BIOLOX delta Ceramic Femoral Head is used in conjunction with compatible acetabular and femoral stem components in total hip arthroplasty. A variety of sizes and neck lengths are available for various patient anatomies and adjustment of the tension of the ligaments and reconstruction of the center of the natural head of the femur.
Class I - DangerousWhat Should You Do?
- Check if you have this product: Item numbers: 00-8775-028-01; 00-8775-028-02; 00-8775-028-03; 00-8775-032-01; 00-8775-032-02; 00-8775-032-03; 00-8775-032-04; 00-8775-036-01; 00-8775-036-02; 00-8775-036-03; 00-8775-036-04; 00-8775-040-01; 00-8775-040-02; 00-8775-040-03; 00-8775-040-04. Lot #'s: 2524205, 2527529, 2531817, 2543976, 2547030, 2522713, 2535758, 2541605, 2544263, 2538145, 2541613, 2524241, 2524242, 2535756, 2535757, 2538147, 2538184, 2543978, 2543979, 2549572, 2553888, 2557023, 2559372, 2524199, 2524200, 2527535, 2527536, 2527537, 2532038, 2535759, 2535765, 2535766, 2538148, 2538149, 2538152, 2538186, 2545261, 2546980, 2548230, 2551239, 2554875, 2557033, 2524204, 2527538, 2527539, 2538153, 2538189, 2544167, 2551250, 2556148, 2557156, 2535768, 2538190, 2541618, 2544169, 2552353, 2524244, 2524260, 2524261, 2527546, 2527547, 2531818, 2535769, 2535770, 2538165, 2538167, 2538168, 2541619, 2541620, 2544176, 2544177, 2547032, 2552354, 2552365, 2522849, 2524201, 2524202, 2524203, 2527548, 2527549, 2527590, 2531774, 2531815, 2531816, 2538169, 2538170, 2538171, 2538173, 2538175, 2538176, 2541852, 2541853, 2544189, 2544190, 2544191, 2548154, 2552367, 2552368, 2554887, 2554888, 2556180, 2557159, 2557170, 2524262, 2524263, 2527592, 2527593, 2531819, 2535772, 2538177, 2538178, 2538180, 2541866, 2544196, 2545262, 2548170, 2552369, 2556181, 2538191, 2541868, 2524271, 2527594, 2538194, 2538195, 2541869, 2541910, 2541911, 2544198, 2557173, 2568103, 2568982, 2582562, 2583925, 2590223, 2591046, 2591047, 2596627, 2597821, 2600144, 2602748, 2615192, 2617666, 2618635, 2621751, 2623054, 2632524, 2633562, 2635942, 2638898, 2641867, 2642795, 2645303, 2647759, 2651994, 2531222, 2538196, 2538197, 2541912, 2541913, 2544253, 2545245, 2558285, 2566263, 2566672, 2568104, 2570197, 2576875, 2576876, 2583926, 2591048, 2591049, 2596628, 2596954, 2596960, 2599455, 2602729, 2605035, 2606707, 2608757, 2614031, 2616153, 2618045, 2620408, 2622735, 2623070, 2628694, 2629838, 2633563, 2634788, 2637813, 2638899, 2639802, 2641868, 2642796, 2642797, 2645304, 2648615, 2651105, 2651106, 2524272, 2527606, 2538198, 2541914, 2541925, 2544254, 2567876, 2568983, 2573850, 2583927, 2591050, 2591051, 2597822, 2602735, 2606708, 2615193, 2618046, 2620409, 2627501, 2629839, 2632525, 2634789, 2638910, 2639803, 2642798, 2645305, 2647760, 2538199, 2538200, 2541926, 2541927, 2541928, 2544260, 2545246, 2573846, 2583928, 2591076, 2597823, 2601623, 2610484, 2617667, 2622736, 2627924, 2629840, 2634790, 2639808, 2639809, 2642799, 2646184, 2647761, 2648617, 2651108
- Do not eat it: Even if it looks and smells fine, do not consume this product.
- Throw it away or return it: You can return the product to the store for a full refund.
- Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
- Report problems: Report any issues to the FDA's Safety Reporting Portal.
⚠️ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.
Recall Details
- Company:
- Zimmer Gmbh
- Reason for Recall:
- Potential compromise of the inner sterile tray. If a compromised tray is detected, a delay in surgery may result. If undetected breach in both the inner and outer trays were to occur, and there is contamination present, a periprosthetic infection is possible, which could lead to revision.
- Classification:
- Class I - Dangerous
Dangerous or defective products that predictably could cause serious health problems or death.
- Status:
- terminated
Product Information
Full Description:
Biolox Delta Femoral Head - The BIOLOX delta Ceramic Femoral Head is used in conjunction with compatible acetabular and femoral stem components in total hip arthroplasty. A variety of sizes and neck lengths are available for various patient anatomies and adjustment of the tension of the ligaments and reconstruction of the center of the natural head of the femur.
Product Codes/Lot Numbers:
Item numbers: 00-8775-028-01; 00-8775-028-02; 00-8775-028-03; 00-8775-032-01; 00-8775-032-02; 00-8775-032-03; 00-8775-032-04; 00-8775-036-01; 00-8775-036-02; 00-8775-036-03; 00-8775-036-04; 00-8775-040-01; 00-8775-040-02; 00-8775-040-03; 00-8775-040-04. Lot #'s: 2524205, 2527529, 2531817, 2543976, 2547030, 2522713, 2535758, 2541605, 2544263, 2538145, 2541613, 2524241, 2524242, 2535756, 2535757, 2538147, 2538184, 2543978, 2543979, 2549572, 2553888, 2557023, 2559372, 2524199, 2524200, 2527535, 2527536, 2527537, 2532038, 2535759, 2535765, 2535766, 2538148, 2538149, 2538152, 2538186, 2545261, 2546980, 2548230, 2551239, 2554875, 2557033, 2524204, 2527538, 2527539, 2538153, 2538189, 2544167, 2551250, 2556148, 2557156, 2535768, 2538190, 2541618, 2544169, 2552353, 2524244, 2524260, 2524261, 2527546, 2527547, 2531818, 2535769, 2535770, 2538165, 2538167, 2538168, 2541619, 2541620, 2544176, 2544177, 2547032, 2552354, 2552365, 2522849, 2524201, 2524202, 2524203, 2527548, 2527549, 2527590, 2531774, 2531815, 2531816, 2538169, 2538170, 2538171, 2538173, 2538175, 2538176, 2541852, 2541853, 2544189, 2544190, 2544191, 2548154, 2552367, 2552368, 2554887, 2554888, 2556180, 2557159, 2557170, 2524262, 2524263, 2527592, 2527593, 2531819, 2535772, 2538177, 2538178, 2538180, 2541866, 2544196, 2545262, 2548170, 2552369, 2556181, 2538191, 2541868, 2524271, 2527594, 2538194, 2538195, 2541869, 2541910, 2541911, 2544198, 2557173, 2568103, 2568982, 2582562, 2583925, 2590223, 2591046, 2591047, 2596627, 2597821, 2600144, 2602748, 2615192, 2617666, 2618635, 2621751, 2623054, 2632524, 2633562, 2635942, 2638898, 2641867, 2642795, 2645303, 2647759, 2651994, 2531222, 2538196, 2538197, 2541912, 2541913, 2544253, 2545245, 2558285, 2566263, 2566672, 2568104, 2570197, 2576875, 2576876, 2583926, 2591048, 2591049, 2596628, 2596954, 2596960, 2599455, 2602729, 2605035, 2606707, 2608757, 2614031, 2616153, 2618045, 2620408, 2622735, 2623070, 2628694, 2629838, 2633563, 2634788, 2637813, 2638899, 2639802, 2641868, 2642796, 2642797, 2645304, 2648615, 2651105, 2651106, 2524272, 2527606, 2538198, 2541914, 2541925, 2544254, 2567876, 2568983, 2573850, 2583927, 2591050, 2591051, 2597822, 2602735, 2606708, 2615193, 2618046, 2620409, 2627501, 2629839, 2632525, 2634789, 2638910, 2639803, 2642798, 2645305, 2647760, 2538199, 2538200, 2541926, 2541927, 2541928, 2544260, 2545246, 2573846, 2583928, 2591076, 2597823, 2601623, 2610484, 2617667, 2622736, 2627924, 2629840, 2634790, 2639808, 2639809, 2642799, 2646184, 2647761, 2648617, 2651108
Distribution:
Nationwide distribution
Official Source
Always verify recall information with the official FDA source:
View on FDA.govFDA Recall Number: Z-1134-2015
Related Recalls
Mislabeled: Incorrect sleeve in the packaging. The outer packaging is labeled as a standard neck sleeve, however, the product within the box is a -6mm neck sleeve, and vice versa. The neck of the sleeve can be identified by the device etching as either STD or -6
Mislabeled: Incorrect sleeve in the packaging. The outer packaging is labeled as a standard neck sleeve, however, the product within the box is a -6mm neck sleeve, and vice versa. The neck of the sleeve can be identified by the device etching as either STD or -6
Zimmer Natural Nail (ZNN) System-CMN Femoral Nail potential commingle between CCD angle 130 degree and 125 degree