ZUK PRC FEM SZB RMED/LLAT¿ ZUK PRC FEM SZC LMED/RLAT¿ ZUK PRC FEM SZC RMED/LLAT¿ NGU PRC FEM SZD LMED/RLAT¿ ZUK PRC FEM SZD RMED/LLAT¿ ZUK PRC FEM SZE LMED/RLAT ZUK PRC FEM SZF RMED/LLAT " These devices are indicated for patients with: - Painful and/or disabling knee joints due to osteoarthritis or traumatic arthritis. - Previous tibial condyle or plateau fractures with loss of anatomy or function. - Varus or valgus deformities. - Revision of previous arthroplasty procedures. " These devices are indicated for cemented use only. " The Zimmer Unicompartmental Knee System is designed for use when load bearing ROM is expected to be less than or equal to 155 degrees.

Class I - Dangerous

What Should You Do?

  1. Check if you have this product:
    00-5842-012-02 61777606 00-5842-012-02 61774093 00-5842-013-01 61774095 00-5842-013-02 61777611 00-5842-014-01 11002921 00-5842-014-01 61777613 00-5842-014-02 61777615 00-5842-014-02 61777616 00-5842-015-01 61777617 00-5842-016-02 61756843
  2. Do not eat it: Even if it looks and smells fine, do not consume this product.
  3. Throw it away or return it: You can return the product to the store for a full refund.
  4. Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
  5. Report problems: Report any issues to the FDA's Safety Reporting Portal.

⚠️ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.

Recall Details

Company:
Zimmer Biomet, Inc.
Reason for Recall:
The LDPE bag packaging for various highly polished hip and knee implants may adhere to the highly polished surface, leaving residue or material from the LDPE bag on the implant after it is removed from the bag.
Classification:
Class I - Dangerous

Dangerous or defective products that predictably could cause serious health problems or death.

Status:
terminated

Product Information

Full Description:

ZUK PRC FEM SZB RMED/LLAT¿ ZUK PRC FEM SZC LMED/RLAT¿ ZUK PRC FEM SZC RMED/LLAT¿ NGU PRC FEM SZD LMED/RLAT¿ ZUK PRC FEM SZD RMED/LLAT¿ ZUK PRC FEM SZE LMED/RLAT ZUK PRC FEM SZF RMED/LLAT " These devices are indicated for patients with: - Painful and/or disabling knee joints due to osteoarthritis or traumatic arthritis. - Previous tibial condyle or plateau fractures with loss of anatomy or function. - Varus or valgus deformities. - Revision of previous arthroplasty procedures. " These devices are indicated for cemented use only. " The Zimmer Unicompartmental Knee System is designed for use when load bearing ROM is expected to be less than or equal to 155 degrees.

Product Codes/Lot Numbers:

00-5842-012-02 61777606 00-5842-012-02 61774093 00-5842-013-01 61774095 00-5842-013-02 61777611 00-5842-014-01 11002921 00-5842-014-01 61777613 00-5842-014-02 61777615 00-5842-014-02 61777616 00-5842-015-01 61777617 00-5842-016-02 61756843

Official Source

Always verify recall information with the official FDA source:

View on FDA.gov

FDA Recall Number: Z-1054-2018

Related Recalls

Zimmer Biomet is conducting a medical device correction to update the Instructions for Use (IFU) and the Surgical Techniques for the Polaris Spinal System Translation Screw and Cypher MIS Screw System. Users should be aware that changes were made to the contraindications section indicating that the Translation Screws should not be used with a direct current stimulation, as a high probability of construct failure exists when using Translation Screws containing CoCr with direct current simulation system.

Nov 17, 2020 Other Medical Devices Nationwide View Details →