AF w/AS 550 x 1-14 ml/hr, 5ml30 LOCPNB, Product code MVBX30XLCPNB, Arrow AutoFuser Disposable Pain Control Pump

Class I - Dangerous

What Should You Do?

  1. Check if you have this product:
    74M1500647 74G1702789
  2. Do not eat it: Even if it looks and smells fine, do not consume this product.
  3. Throw it away or return it: You can return the product to the store for a full refund.
  4. Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
  5. Report problems: Report any issues to the FDA's Safety Reporting Portal.

⚠️ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.

Recall Details

Company:
Arrow International Inc
Reason for Recall:
Possible cracks on the body of the fill port connector, which may result in a leak. If the leak is identified while the user is filling the pump, there may be a delay while an alternative pump is located. If the leak goes undetected it may result in a reduced level of drug delivery to the patient and consequently a lower level of pain relief than that prescribed or expected. This may result in the need for other, additional analgesic drug administration.
Classification:
Class I - Dangerous

Dangerous or defective products that predictably could cause serious health problems or death.

Status:
terminated

Product Information

Full Description:

AF w/AS 550 x 1-14 ml/hr, 5ml30 LOCPNB, Product code MVBX30XLCPNB, Arrow AutoFuser Disposable Pain Control Pump

Product Codes/Lot Numbers:

74M1500647 74G1702789

Official Source

Always verify recall information with the official FDA source:

View on FDA.gov

FDA Recall Number: Z-0953-2019

Related Recalls

Arrow Arterial Kits and Trays as follows: (1) Arrow Arterial Access Tray with 0.025" Spring-Wire Guide (Catheter Not Included), REF ASK-04001-BW1; (2) Arrow Arterial Access Tray with 0.021" Spring-Wire Guide (Catheter Not Included), REF ASK-04001-CK; (3) Arrow Arterial Access Kit, .025 inch dia. spring-wire guide, REF ASK-04001-VAMC1; (4) Arrow Arterial Catheterization Kit, 20 Ga., 4.45 cm catheter length, .018 inch dia. spring-wire guide, REF ASK-04020-BHS; (5) Arrow Arterial Catheterization Kit, 20 Ga., 4.45 cm catheter length, .025 inch dia. spring-wire guide, REF ASK-04020-BID; (6) Arrow Arterial Line Kit, 20 Ga., 12 cm. catheter length, .025 inch dia. spring-wire guide, REF ASK-04020-HMC; (7) Arrow Arterial Catheterization Kit, 20 Ga. 4.45 cm catheter length, .018 inch dia. spring-wire guide, REF ASK-04020-HOA; (8) Arrow Arterial Catheterization Kit, 20 Ga., 4.45 cm. catheter length, .018 inch dia. spring-wire guide, REF ASK-04020-KSD; (9) Arrow Arterial Catheterization Kit, 20 Ga. 4.45 cm catheter length, .018 inch dia. spring-wire guide, REF ASK-04020-LOL; (10) Arrow Radial Catheterization, 20 Ga. 4.45 cm catheter length, .018 inch dia. spring-wire guide, REF ASK-04020-MHS; (11) Arrow Arterial Catheterization Kit, 20 Ga., 4.45 cm catheter length, 018 inch dia. spring-wire guide, REF ASK-04020-MIB3; (12) Arrow Arterial Catheterization Kit, 20 Ga., 4.45 cm catheter length, .018 dia. spring- wire guide, REF ASK-04020-PRH; (13) Arrow Arterial Catheterization Kit, 20 Ga., 4.45 cm catheter length, .018 dia. spring-wire guide, REF ASK-04020-UOIL; (14) Arrow QuickFlash Radial Artery Catheterization Kit, 20 Ga., 3.81 cm catheter length, .018 inch dia. spring-wire guide, REF ASK-04220-KSP; and (15) Arrow Arterial Catheterization Kit, 20 Ga. 4.45/12 cm catheter length, .018 inch dia. spring-wire guide, REF ASK-04500-HFH4.

ARROW INTERNATIONAL

Class I - Dangerous

Reports have been received regarding open seals on the packaging.

Jul 26, 2024 Surgical Instruments Nationwide View Details →

Teleflex received reports indicating an infrequent condition that, when not identified and corrected promptly, could result in serious health consequences. The issue may manifest as: -failure of the intra-aortic balloon to completely inflate over its full length -damaged or broken central lumen in the segment contained within the balloon -helium loss or blood in the helium pathway.

Apr 29, 2024 Surgical Instruments Nationwide View Details →

Teleflex received reports indicating an infrequent condition that, when not identified and corrected promptly, could result in serious health consequences. The issue may manifest as: -failure of the intra-aortic balloon to completely inflate over its full length -damaged or broken central lumen in the segment contained within the balloon -helium loss or blood in the helium pathway.

Apr 29, 2024 Surgical Instruments Nationwide View Details →