HORIZON Ez Arm (Part of the HORIZON TMS Therapy System.)
Class I - DangerousWhat Should You Do?
- Check if you have this product: Product #: 5162-00 Serial #'s: 55308/001, 55308/002, 55310/001, 55310/002, 55446/001, 55446/002, 55447/001, 55447-002, 55631-001, 55631-002, 55631-003, 55631-004, 55632/001, 55632/002, 55632/003, 55632/004, 55841/001, 55841-002, 55841-003, 55841-004, 55842/001, 55842/002, 55842/003, 55842/004, 55843-001, PLT00015/001 and PLT00015/002
- Do not eat it: Even if it looks and smells fine, do not consume this product.
- Throw it away or return it: You can return the product to the store for a full refund.
- Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
- Report problems: Report any issues to the FDA's Safety Reporting Portal.
⚠️ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.
Recall Details
- Company:
- The Magstim Company Limited
- Reason for Recall:
- A stray strand of stainless-steel cable may protrude from the heat shrink sleeving on the Balance Cable of the Ez Arm.
- Classification:
- Class I - Dangerous
Dangerous or defective products that predictably could cause serious health problems or death.
- Status:
- ongoing
Product Information
Full Description:
HORIZON Ez Arm (Part of the HORIZON TMS Therapy System.)
Product Codes/Lot Numbers:
Product #: 5162-00 Serial #'s: 55308/001, 55308/002, 55310/001, 55310/002, 55446/001, 55446/002, 55447/001, 55447-002, 55631-001, 55631-002, 55631-003, 55631-004, 55632/001, 55632/002, 55632/003, 55632/004, 55841/001, 55841-002, 55841-003, 55841-004, 55842/001, 55842/002, 55842/003, 55842/004, 55843-001, PLT00015/001 and PLT00015/002
Distribution:
Distributed in: CA, MA, MN, PA, TX, VA, WI, WA
Official Source
Always verify recall information with the official FDA source:
View on FDA.govFDA Recall Number: Z-0836-2019
Related Recalls
Neurosign 100, Product Number 9883-01. Intraoperative Nerve Monitor - Product Usage: indicated for use in stimulating and monitoring cranial motor nerves, especially the facial nerve (VII), during ENT surgical procedures.
The Magstim Company Limited
A small number of Neurosign 100 Intraoperative Nerve Monitors may have been dispatched without being configured appropriately for the supply mains within the target Country. The specific deficiency includes: 1. Onboard voltage selector set to 240V (European Standard), versus 120V requirement for the United States and Canada. 2. Fuses installed in the Power Entry Module (PEM) 2xT315mAL (240V Standard), versus the 2xT630mAL requirement for a 120V mains supply.
Neurosign V4 Intraoperative Nerve monitor family of devices.
The Magstim Company Limited
Reports that manipulation of the cable which connects the pre-amplifier to the nerve monitor, and the cable which connects the pre-amplifier to the stimulator pod, may cause damage to the internal construction of the cables.
It was identified that there is a potential for the Stim Interconnecting high Voltage Cable located at the rear of the Rapid2 and Horizon power supply unit to fail.