Perkin Elmer WIZARD2 1-detector,3", 1000 samples. Product Code: 2480-0010 The Wizard gamma counter is intended to detect and count gamma radiation emitted by clinical samples

Class I - Dangerous

What Should You Do?

  1. Check if you have this product:
    Serial Numbers: DG12107256 DG04106256 DG08118161 DG03117633 DG09118348 DG06117938 DG04106271 DG03117625 DG11118603 DG03129003 DG11107087 DG09118269 DG09118346 DG09118323 DG09118410 DG10118462 DG12118695 DG03129030 DG05117802 DG04129089 DG11107086 DG03117631 DG10118453 DG01117421 DG04106256_REWORK DG06106456 DG03106146 DG11118564 DG03129000 DG02106095 DG08106711 DG02128912 DG10106940 DG07118046 DG07118051 DG03117635 DG09118273 DG05117890 DG12118657 DG09118349 DG03117557 DG10118483 DG10118478 DG11107160 DG04129156 DG02106081 DG09118167 DG02128958 DG03129032 DG03117634 DG11118575 DG08118256 DG05106334 DG10106910 DG10106950 DG03117630 DG05106409 DG07106656 DG12107176 DG05106333 DG05117810 DG10106978 DG03106122 DG12107186 DG08106662 DG05117817 DG05117874 DG02128962 DG11118610 DG03129033 DG03129034 DG12118735 DG11107053 DG09118307 DG07118070 DG09118306 DG08118170 DG02128953 DG02128936 DG03129053 DG08118162 DG11118587 DG03129031 DG02128933 DG03129002 DG03129001 DG08118163 DG02128895 DG10118489 DG02117474 DG09118281 DG09118316 DG10106976 DG06117966 DG06106504 DG08118168 DG08118169 DG11118545 DG01128861 DG10118448 DG10118458 DG10118474 DG10118458 DG10118472 DG01128794 DG03129055 DG09118321 DG07118071 DG10118440 DG02128879 DG03117632 DG10118408 DG02128927 DG06106505 DG10118418 DG01128802 DG12118717 DG12118769 DG12118783 DG01106026 DG09106876 DG03129068 DG05106332 DG01105987 DG03106128 DG10118388 DG08118165 DG01128850 DG06117937 DG06117936 DG06117939 DG08118166 DG04117759 DG11118579 DG10118424 DG01128854 DG01128856 DG12107271 DG11118623 DG08118164 DG01128829 DG09118312 DG06117986 DG03106165 DG12118688 DG05117847 DG10118417 DG02128918 DG04106222 DG06106437 DG11118584 DG03117571 DG09118290 DG09106811 DG12107248 DG04106273 DG08106755 DG10106977 DG10106938 DG06117987 DG03106136 DG12118727 DG02128898 DG06106464 DG11107127 DG05106395 DG11107034 DG01128809 DG11118596 DG04129132 DG09106843 DG02117463 DG02106083 DG09118289 DG03117597 DG12107197 DG02117542 DG12118710 DG01128838 DG11118535 DG10118499 DG10118502 DG10118519 DG11118526 DG05117780 DG11118528 DG03117628 DG12118749
  2. Do not eat it: Even if it looks and smells fine, do not consume this product.
  3. Throw it away or return it: You can return the product to the store for a full refund.
  4. Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
  5. Report problems: Report any issues to the FDA's Safety Reporting Portal.

⚠️ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.

Recall Details

Company:
Perkinelmer
Reason for Recall:
The content of the second #023 barcode ID label in the Barcode ID Label Binder is incorrect. The second barcode ID label #023 symbol incorrectly identifies as #024 when scanned. If measurement protocols have been programmed for both ID #023 and #024, the protocol associated with barcode ID #024 is executed. If the error is undetected, the Gamma Counter may produce erroneous results.
Classification:
Class I - Dangerous

Dangerous or defective products that predictably could cause serious health problems or death.

Status:
terminated

Product Information

Full Description:

Perkin Elmer WIZARD2 1-detector,3", 1000 samples. Product Code: 2480-0010 The Wizard gamma counter is intended to detect and count gamma radiation emitted by clinical samples

Product Codes/Lot Numbers:

Serial Numbers: DG12107256 DG04106256 DG08118161 DG03117633 DG09118348 DG06117938 DG04106271 DG03117625 DG11118603 DG03129003 DG11107087 DG09118269 DG09118346 DG09118323 DG09118410 DG10118462 DG12118695 DG03129030 DG05117802 DG04129089 DG11107086 DG03117631 DG10118453 DG01117421 DG04106256_REWORK DG06106456 DG03106146 DG11118564 DG03129000 DG02106095 DG08106711 DG02128912 DG10106940 DG07118046 DG07118051 DG03117635 DG09118273 DG05117890 DG12118657 DG09118349 DG03117557 DG10118483 DG10118478 DG11107160 DG04129156 DG02106081 DG09118167 DG02128958 DG03129032 DG03117634 DG11118575 DG08118256 DG05106334 DG10106910 DG10106950 DG03117630 DG05106409 DG07106656 DG12107176 DG05106333 DG05117810 DG10106978 DG03106122 DG12107186 DG08106662 DG05117817 DG05117874 DG02128962 DG11118610 DG03129033 DG03129034 DG12118735 DG11107053 DG09118307 DG07118070 DG09118306 DG08118170 DG02128953 DG02128936 DG03129053 DG08118162 DG11118587 DG03129031 DG02128933 DG03129002 DG03129001 DG08118163 DG02128895 DG10118489 DG02117474 DG09118281 DG09118316 DG10106976 DG06117966 DG06106504 DG08118168 DG08118169 DG11118545 DG01128861 DG10118448 DG10118458 DG10118474 DG10118458 DG10118472 DG01128794 DG03129055 DG09118321 DG07118071 DG10118440 DG02128879 DG03117632 DG10118408 DG02128927 DG06106505 DG10118418 DG01128802 DG12118717 DG12118769 DG12118783 DG01106026 DG09106876 DG03129068 DG05106332 DG01105987 DG03106128 DG10118388 DG08118165 DG01128850 DG06117937 DG06117936 DG06117939 DG08118166 DG04117759 DG11118579 DG10118424 DG01128854 DG01128856 DG12107271 DG11118623 DG08118164 DG01128829 DG09118312 DG06117986 DG03106165 DG12118688 DG05117847 DG10118417 DG02128918 DG04106222 DG06106437 DG11118584 DG03117571 DG09118290 DG09106811 DG12107248 DG04106273 DG08106755 DG10106977 DG10106938 DG06117987 DG03106136 DG12118727 DG02128898 DG06106464 DG11107127 DG05106395 DG11107034 DG01128809 DG11118596 DG04129132 DG09106843 DG02117463 DG02106083 DG09118289 DG03117597 DG12107197 DG02117542 DG12118710 DG01128838 DG11118535 DG10118499 DG10118502 DG10118519 DG11118526 DG05117780 DG11118528 DG03117628 DG12118749

Official Source

Always verify recall information with the official FDA source:

View on FDA.gov

FDA Recall Number: Z-0638-2016

Related Recalls

Defective tips have the potential to pipette/dispense volumes 50-100% lower than is specified for the tips.

Oct 13, 2016 Other Medical Devices View Details →

Filter Tips molded incorrectly and may not seal to the Varispan tip adaptor properly causing inaccurate aspiration and dispensing

Jun 24, 2016 Surgical Instruments View Details →

The content of the second #023 barcode ID label in the Barcode ID Label Binder is incorrect. The second barcode ID label #023 symbol incorrectly identifies as #024 when scanned. If measurement protocols have been programmed for both ID #023 and #024, the protocol associated with barcode ID #024 is executed. If the error is undetected, the Gamma Counter may produce erroneous results.

Dec 8, 2015 Other Medical Devices Nationwide View Details →