Perkin Elmer WIZARD2 10-detector, 1000 samples. Product Code: 2470-0200, 3470-0200. The Wizard gamma counter is intended to detect and count gamma radiation emitted by clinical samples

Class I - Dangerous

What Should You Do?

  1. Check if you have this product:
    Serial Numbes: DG08118243 DG12118732 DG09106871 DG03117554 DG05106373 DG02117481 DG11107153 DG07118106 DG03128981 DG04106316 DG03117574 DG04106296 DG04117674 DG05106414 DG02117455 DG07106607 DG11107048 DG03106163 DG07106604 DG05117805 DG08106759 DG03129008
  2. Do not eat it: Even if it looks and smells fine, do not consume this product.
  3. Throw it away or return it: You can return the product to the store for a full refund.
  4. Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
  5. Report problems: Report any issues to the FDA's Safety Reporting Portal.

⚠️ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.

Recall Details

Company:
Perkinelmer
Reason for Recall:
The content of the second #023 barcode ID label in the Barcode ID Label Binder is incorrect. The second barcode ID label #023 symbol incorrectly identifies as #024 when scanned. If measurement protocols have been programmed for both ID #023 and #024, the protocol associated with barcode ID #024 is executed. If the error is undetected, the Gamma Counter may produce erroneous results.
Classification:
Class I - Dangerous

Dangerous or defective products that predictably could cause serious health problems or death.

Status:
terminated

Product Information

Full Description:

Perkin Elmer WIZARD2 10-detector, 1000 samples. Product Code: 2470-0200, 3470-0200. The Wizard gamma counter is intended to detect and count gamma radiation emitted by clinical samples

Product Codes/Lot Numbers:

Serial Numbes: DG08118243 DG12118732 DG09106871 DG03117554 DG05106373 DG02117481 DG11107153 DG07118106 DG03128981 DG04106316 DG03117574 DG04106296 DG04117674 DG05106414 DG02117455 DG07106607 DG11107048 DG03106163 DG07106604 DG05117805 DG08106759 DG03129008

Official Source

Always verify recall information with the official FDA source:

View on FDA.gov

FDA Recall Number: Z-0637-2016

Related Recalls

Defective tips have the potential to pipette/dispense volumes 50-100% lower than is specified for the tips.

Oct 13, 2016 Other Medical Devices View Details →

Filter Tips molded incorrectly and may not seal to the Varispan tip adaptor properly causing inaccurate aspiration and dispensing

Jun 24, 2016 Surgical Instruments View Details →

The content of the second #023 barcode ID label in the Barcode ID Label Binder is incorrect. The second barcode ID label #023 symbol incorrectly identifies as #024 when scanned. If measurement protocols have been programmed for both ID #023 and #024, the protocol associated with barcode ID #024 is executed. If the error is undetected, the Gamma Counter may produce erroneous results.

Dec 8, 2015 Other Medical Devices Nationwide View Details →