Perkin Elmer ClWIZARD2 5-detector, 550 samples Product Code: 2470-0050, 3470-0050. The Wizard2 gamma counter is intended to detect and count gamma radiation emitted by clinical samples.

Class I - Dangerous

What Should You Do?

  1. Check if you have this product:
    Model: 2470-0050 Serial Numbers: DG05106329 DG02117493 DG11107166 DG09106782 DG07118133 DG07118141 DG09106791 DG04117727 DG06118036 DG12107192 DG02106101 DG04106223 DG01128843 DG12107272 DG07118124 DG09106892 DG12118684 DG12118673 DG11107126 DG04117704 DG04117763 DG01117363 DG06106484 DG12107240 DG01128871 DG05117880 DG12118685 DG09118357 DG03106204 DG05106386 DG11107137 DG03106172 DG03106206 DG02106113 DG09106818 DG02106065 DG04106309 DG09106882 DG11118590 DG06106483 DG01117316 DG08118221 DG06117898 DG12107263 DG08118250 DG12118711 DG04117710 DG06106448 DG06106453 DG06106463 DG06117912 DG03106135 DG01117373 DG05117837 DG06106517 DG01128805 DG06117970 DG04106310 DG02117521 DG06106538 Model: 3470-0050 (2 units) Serial Numbers: DG12118660 DG10118464
  2. Do not eat it: Even if it looks and smells fine, do not consume this product.
  3. Throw it away or return it: You can return the product to the store for a full refund.
  4. Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
  5. Report problems: Report any issues to the FDA's Safety Reporting Portal.

⚠️ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.

Recall Details

Company:
Perkinelmer
Reason for Recall:
The content of the second #023 barcode ID label in the Barcode ID Label Binder is incorrect. The second barcode ID label #023 symbol incorrectly identifies as #024 when scanned. If measurement protocols have been programmed for both ID #023 and #024, the protocol associated with barcode ID #024 is executed. If the error is undetected, the Gamma Counter may produce erroneous results.
Classification:
Class I - Dangerous

Dangerous or defective products that predictably could cause serious health problems or death.

Status:
terminated

Product Information

Full Description:

Perkin Elmer ClWIZARD2 5-detector, 550 samples Product Code: 2470-0050, 3470-0050. The Wizard2 gamma counter is intended to detect and count gamma radiation emitted by clinical samples.

Product Codes/Lot Numbers:

Model: 2470-0050 Serial Numbers: DG05106329 DG02117493 DG11107166 DG09106782 DG07118133 DG07118141 DG09106791 DG04117727 DG06118036 DG12107192 DG02106101 DG04106223 DG01128843 DG12107272 DG07118124 DG09106892 DG12118684 DG12118673 DG11107126 DG04117704 DG04117763 DG01117363 DG06106484 DG12107240 DG01128871 DG05117880 DG12118685 DG09118357 DG03106204 DG05106386 DG11107137 DG03106172 DG03106206 DG02106113 DG09106818 DG02106065 DG04106309 DG09106882 DG11118590 DG06106483 DG01117316 DG08118221 DG06117898 DG12107263 DG08118250 DG12118711 DG04117710 DG06106448 DG06106453 DG06106463 DG06117912 DG03106135 DG01117373 DG05117837 DG06106517 DG01128805 DG06117970 DG04106310 DG02117521 DG06106538 Model: 3470-0050 (2 units) Serial Numbers: DG12118660 DG10118464

Official Source

Always verify recall information with the official FDA source:

View on FDA.gov

FDA Recall Number: Z-0634-2016

Related Recalls

Defective tips have the potential to pipette/dispense volumes 50-100% lower than is specified for the tips.

Oct 13, 2016 Other Medical Devices View Details →

Filter Tips molded incorrectly and may not seal to the Varispan tip adaptor properly causing inaccurate aspiration and dispensing

Jun 24, 2016 Surgical Instruments View Details →

The content of the second #023 barcode ID label in the Barcode ID Label Binder is incorrect. The second barcode ID label #023 symbol incorrectly identifies as #024 when scanned. If measurement protocols have been programmed for both ID #023 and #024, the protocol associated with barcode ID #024 is executed. If the error is undetected, the Gamma Counter may produce erroneous results.

Dec 8, 2015 Other Medical Devices Nationwide View Details →