SOL SYS L 9IN CALC 2.25/15.0 Packaging: Product is packed within a poly protector, with protection added as needed for fragile points. The entire stem is then placed within a foam sleeve for added protection. The assembly is then placed and sealed in an inner and outer tray for aseptic transfer. The sealed package is placed into a folding carton, labeled, and shrink wrapped. Intended Use: SOLUTION System Calcar Stems are used in total hip arthroplasty (THA) to provide increased patient mobility and reduce pain by replacing the damaged hip joint articulation in patients where there is evidence of sufficient sound bone to seat and support the components.

Class I - Dangerous

What Should You Do?

  1. Check if you have this product:
    Product Code: 157225150 and Lot codes: 107076, X4SE71000, 117308, X4SE7A000, A38B51000, X4SE7B000, AV3DR1000, YA9BN1000, B2DB11000, YF3E71000, BA4GR1000, YF3E7A000, BA4GRA000, YG4AF1000, BC4HR1000, Z47HE1000, C49A61000, Z4RJE1000, C6ACN1000, Z81H61000, C77A61000, CD1ER1000, , CD1ERA000, CK3E21000, CK3E2A, CY4GB1000, DX7J21000, DX7J2A000, E3FH61000, E4HB41000, E5DDA1000, E6BKR1, EJ4EH1000, EW9J61000, X32HH1000, X43C71000, X43C91000, and X43C9B000.
  2. Do not eat it: Even if it looks and smells fine, do not consume this product.
  3. Throw it away or return it: You can return the product to the store for a full refund.
  4. Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
  5. Report problems: Report any issues to the FDA's Safety Reporting Portal.

⚠️ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.

Recall Details

Company:
DePuy Orthopaedics, Inc.
Reason for Recall:
An Engineering Analysis has determined the Solution Calcar Stem has the potential to result in impingement with a variety of heads. This impingement may not allow the stem and head to lock as intended. The amount of possible impingement varies depending on the femoral head. Worst case condition: Calcar stem with -2mm offset articuleze maximum of 0.937mm radial impingement. It is evident that a
Classification:
Class I - Dangerous

Dangerous or defective products that predictably could cause serious health problems or death.

Status:
terminated

Product Information

Full Description:

SOL SYS L 9IN CALC 2.25/15.0 Packaging: Product is packed within a poly protector, with protection added as needed for fragile points. The entire stem is then placed within a foam sleeve for added protection. The assembly is then placed and sealed in an inner and outer tray for aseptic transfer. The sealed package is placed into a folding carton, labeled, and shrink wrapped. Intended Use: SOLUTION System Calcar Stems are used in total hip arthroplasty (THA) to provide increased patient mobility and reduce pain by replacing the damaged hip joint articulation in patients where there is evidence of sufficient sound bone to seat and support the components.

Product Codes/Lot Numbers:

Product Code: 157225150 and Lot codes: 107076, X4SE71000, 117308, X4SE7A000, A38B51000, X4SE7B000, AV3DR1000, YA9BN1000, B2DB11000, YF3E71000, BA4GR1000, YF3E7A000, BA4GRA000, YG4AF1000, BC4HR1000, Z47HE1000, C49A61000, Z4RJE1000, C6ACN1000, Z81H61000, C77A61000, CD1ER1000, , CD1ERA000, CK3E21000, CK3E2A, CY4GB1000, DX7J21000, DX7J2A000, E3FH61000, E4HB41000, E5DDA1000, E6BKR1, EJ4EH1000, EW9J61000, X32HH1000, X43C71000, X43C91000, and X43C9B000.

Official Source

Always verify recall information with the official FDA source:

View on FDA.gov

FDA Recall Number: Z-0580-2013

Related Recalls