VNS(R) Therapy Programmer, GMDN: 44077, Model 3000 v1.0.2.2 Intended Use/Indications: United States Indications for Use: Epilepsy : The VNS Therapy System is indicated for use as an adjunctive therapy in reducing the frequency of seizures in patients 4 years of age and older with partial onset seizures that are refractory to antiepileptic medications. Depression : VNS Therapy is indicated for the adjunctive long-term treatment of chronic or recurrent depression for patients 18 years of age or older who are experiencing a major depressive episode and have not had an adequate response to four or more adequate antidepressant treatments.

Class I - Dangerous

What Should You Do?

  1. Check if you have this product:
    Part Number: 10-0011-0500 Serial number/UDI: 8LYB7F2/010542502575039911170920218LYB7F29910-0011-0500 D80C7F2/01054250257503991117092921D80C7F29910-0011-0500
  2. Do not eat it: Even if it looks and smells fine, do not consume this product.
  3. Throw it away or return it: You can return the product to the store for a full refund.
  4. Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
  5. Report problems: Report any issues to the FDA's Safety Reporting Portal.

⚠️ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.

Recall Details

Company:
Cyberonics, Inc
Reason for Recall:
Two Model 3000 Programmers were distributed in error by prior to FDA approval of version 1.0.2.2 software.
Classification:
Class I - Dangerous

Dangerous or defective products that predictably could cause serious health problems or death.

Status:
terminated

Product Information

Full Description:

VNS(R) Therapy Programmer, GMDN: 44077, Model 3000 v1.0.2.2 Intended Use/Indications: United States Indications for Use: Epilepsy : The VNS Therapy System is indicated for use as an adjunctive therapy in reducing the frequency of seizures in patients 4 years of age and older with partial onset seizures that are refractory to antiepileptic medications. Depression : VNS Therapy is indicated for the adjunctive long-term treatment of chronic or recurrent depression for patients 18 years of age or older who are experiencing a major depressive episode and have not had an adequate response to four or more adequate antidepressant treatments.

Product Codes/Lot Numbers:

Part Number: 10-0011-0500 Serial number/UDI: 8LYB7F2/010542502575039911170920218LYB7F29910-0011-0500 D80C7F2/01054250257503991117092921D80C7F29910-0011-0500

Distribution:

Distributed in: US, CO, ND

Official Source

Always verify recall information with the official FDA source:

View on FDA.gov

FDA Recall Number: Z-0555-2018

Related Recalls

Certain Model 3000 programming events can result in miscalculation of parameters stored in the Models 103, 104, 105, and 106 generators. During these programming events, the miscalculations can lead to: " Delivery of more stimulation than intended, resulting in painful stimulation or other common side effects (Model 106 only); " No stimulation in the case of device disablement (Burst Watchdog Timeout), resulting in no therapy to the patient (Model 106 only); " Delivery of less stimulation than intended, resulting in therapeutic settings not being achieved within device specification (Models 103, 104, 105, or 106); and/or " Delays or absence of the 75% and 50% battery life indicators displayed by the programming software (Models 103, 104, 105, or 106).

Nov 13, 2017 Other Medical Devices Nationwide View Details →

Manufacturing process used to assemble the circuit board may result in some devices experiencing a faster than expected reduction in device longevity.

Jun 13, 2017 Infusion Pumps Nationwide View Details →

Manufacturing process used to assemble the circuit board may result in some devices experiencing a faster than expected reduction in device longevity.

Jun 13, 2017 Infusion Pumps Nationwide View Details →