MEDLINE procedure kits labeled as follows: 1) CONT EPI 20G W/HUSTEAD, REF PAIN1069B; 2) CSE TRAY, REF PAIN1941; 3) TRAY CON EPID 20G NYL W/TUOHY, REF PAIN9023; 4) TRAY, CONT EPI 20G NYL W/ HUST, REF PAIN1281 5) TRAY, CONT EPI 20G NYL W/ HUST, REF PAIN9024

Class I - Dangerous

What Should You Do?

  1. Check if you have this product:
    Codes: 1) PAIN1069B UDI-DI: 10889942757381 (each) 40889942757382 (case), Lot Numbers: 22GLA433, 23CLA257; 2) PAIN1941 UDI-DI: 10195327365417 (each) 40195327365418(case), Lot Numbers: 23ELB081; 3) PAIN9023 UDI-DI: 10889942448715(each) 40889942448716 (case), Lot Numbers: 22GLA470, 22ILA287; 4) PAIN1281 UDI-DI: 10888277748408(each) 40888277748409(case), Lot Numbers: 22FLA647; 5) PAIN9024 UDI-DI: 10889942448708(each) 40889942448709(case), Lot Numbers: 22FLA675, 22GLA241, 22HLB225, 22ILA288
  2. Do not eat it: Even if it looks and smells fine, do not consume this product.
  3. Throw it away or return it: You can return the product to the store for a full refund.
  4. Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
  5. Report problems: Report any issues to the FDA's Safety Reporting Portal.

⚠️ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.

Recall Details

Company:
MEDLINE INDUSTRIES, LP - Northfield
Reason for Recall:
The connectors may not allow catheters to be inserted as intended if the connector is not in the fully open position.
Classification:
Class I - Dangerous

Dangerous or defective products that predictably could cause serious health problems or death.

Status:
ongoing

Product Information

Full Description:

MEDLINE procedure kits labeled as follows: 1) CONT EPI 20G W/HUSTEAD, REF PAIN1069B; 2) CSE TRAY, REF PAIN1941; 3) TRAY CON EPID 20G NYL W/TUOHY, REF PAIN9023; 4) TRAY, CONT EPI 20G NYL W/ HUST, REF PAIN1281 5) TRAY, CONT EPI 20G NYL W/ HUST, REF PAIN9024

Product Codes/Lot Numbers:

Codes: 1) PAIN1069B UDI-DI: 10889942757381 (each) 40889942757382 (case), Lot Numbers: 22GLA433, 23CLA257; 2) PAIN1941 UDI-DI: 10195327365417 (each) 40195327365418(case), Lot Numbers: 23ELB081; 3) PAIN9023 UDI-DI: 10889942448715(each) 40889942448716 (case), Lot Numbers: 22GLA470, 22ILA287; 4) PAIN1281 UDI-DI: 10888277748408(each) 40888277748409(case), Lot Numbers: 22FLA647; 5) PAIN9024 UDI-DI: 10889942448708(each) 40889942448709(case), Lot Numbers: 22FLA675, 22GLA241, 22HLB225, 22ILA288

Official Source

Always verify recall information with the official FDA source:

View on FDA.gov

FDA Recall Number: Z-0513-2025

Related Recalls

Medline Industries, LP is issuing a recall for specific item(s) and lot(s) of Medline Kits containing Flexicare BritePro Solo Fiber Optic Laryngoscope Handles due to the failure of the light to illuminate as intended.

Jul 25, 2025 Other Medical Devices View Details →

Medline Industries, LP is issuing a recall for specific item(s) and lot(s) of Medline Kits containing Flexicare BritePro Solo Fiber Optic Laryngoscope Handles due to the failure of the light to illuminate as intended.

Jul 25, 2025 Other Medical Devices View Details →