- Company:
- AROA Biosurgery, LTD.
- Reason for Recall:
- Degradation of the PGA suture material used in the manufacture of the resorbable mesh devices was observed during an on-going product stability study. Further investigation indicated that devices over 18-months showed evidence of no longer meeting the pre-defined ball burst specification respective to the number of tissue layers.
- Classification:
- Class I - Dangerous
Dangerous or defective products that predictably could cause serious health problems or death.
- Status:
- terminated
Product Information
Full Description:
OviTex 1S Reinforced BioScaffold 16x20cm, Part Number F10256-1620G
Product Codes/Lot Numbers:
ERT-6H14 ERT-6J11 ERT-7K09 ERT-7L13
Distribution:
Distributed in: US, AL, CA, FL, IN, MA, MI, NH, NY
Official Source
Always verify recall information with the official FDA source:
View on FDA.govFDA Recall Number: Z-0425-2019
Related Recalls
OviTex 1S Reinforced BioScaffold 4x8cm, Part Number F10256-0408G
AROA Biosurgery
Degradation of the PGA suture material used in the manufacture of the resorbable mesh devices was observed during an on-going product stability study. Further investigation indicated that devices over 18-months showed evidence of no longer meeting the pre-defined ball burst specification respective to the number of tissue layers.
OviTex Reinforced BioScaffold 6x10cm, Part Number F10254-0610G
AROA Biosurgery
Degradation of the PGA suture material used in the manufacture of the resorbable mesh devices was observed during an on-going product stability study. Further investigation indicated that devices over 18-months showed evidence of no longer meeting the pre-defined ball burst specification respective to the number of tissue layers.
Degradation of the PGA suture material used in the manufacture of the resorbable mesh devices was observed during an on-going product stability study. Further investigation indicated that devices over 18-months showed evidence of no longer meeting the pre-defined ball burst specification respective to the number of tissue layers.