EZ Glide Aortic Cannula, 24 Fr. (8.0mm) x 37.6 cm (14.8") 3/8" (9.5 mm) vented connector , RX Only, Sterile EC, Made in Mexico, UDI: 00690103172119 for the following REF #s (UDI): EZC21A (00690103174182), EZC21TA (00690103174199), EZC24A (00690103714401), EZC24TA (00690103714418), EZF21A (00690103175080), EZF21TA (00690103175097), EZF24A (00690103175066), EZF24TA (00690103175073), EZS21A (00690103172096), EZS21TA (00690103172102), EZS24A (00690103172119), and EZS24TA (00690103172126) Product Usage: Aortic perfusion cannulae are intended for perfusion of the ascending aorta during short-term (< 6 hours) cardiopulmonary bypass procedures. Aortic cannulae in sizes 6 Fr. (2 mm) to 18 Fr. (6 mm) can be used in pediatric patient populations.
Class I - DangerousWhat Should You Do?
- Check if you have this product: Lot #s: 203876 207654 217024 226788,205724, 207655, 217025, 226938,205775, 208823, 217048, 227494,205868, 208893, 218185, 227886,205920, 208894, 218457, 228009,205921, 209901, 218539, 228259,205922, 209904, 219090, 228549,206369, 210110, 219212, 228558,206372, 210111, 219561, 229051,206373, 212032 ,220146 ,229054,206374, 212033 ,220151 ,229827,206768, 212034 ,220157 ,230690,206769, 212035 ,220802 ,230894,206770, 212258 ,220803 ,231105,206771, 212280 ,222841 ,231109,206772, 212959 ,222913 ,231111,206773, 213506 ,222914 ,231291,206774, 213914 ,222915 ,231485,206775, 214214 ,223174 ,232109,206776 ,214216 ,224233 ,232437,206777 ,214716 ,224235 ,234138,206778 ,214717 ,224662,207319 ,214961 ,224707,207320 ,215239 ,225306,207321 ,215495 ,225884,207322 ,216123 ,225885,207323 ,216196 ,226188,207324 ,216627 ,226596,207636 ,216628 ,226597,207638 ,216632, 226691
- Do not eat it: Even if it looks and smells fine, do not consume this product.
- Throw it away or return it: You can return the product to the store for a full refund.
- Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
- Report problems: Report any issues to the FDA's Safety Reporting Portal.
⚠️ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.
Recall Details
- Company:
- Edwards Lifesciences, LLC
- Reason for Recall:
- Their is a possibility that the cannula may separate from its connector, potentially causing a breach of circuit during cardiopulmonary bypass which could result in significant blood loss.
- Classification:
- Class I - Dangerous
Dangerous or defective products that predictably could cause serious health problems or death.
- Status:
- terminated
Product Information
Full Description:
EZ Glide Aortic Cannula, 24 Fr. (8.0mm) x 37.6 cm (14.8") 3/8" (9.5 mm) vented connector , RX Only, Sterile EC, Made in Mexico, UDI: 00690103172119 for the following REF #s (UDI): EZC21A (00690103174182), EZC21TA (00690103174199), EZC24A (00690103714401), EZC24TA (00690103714418), EZF21A (00690103175080), EZF21TA (00690103175097), EZF24A (00690103175066), EZF24TA (00690103175073), EZS21A (00690103172096), EZS21TA (00690103172102), EZS24A (00690103172119), and EZS24TA (00690103172126) Product Usage: Aortic perfusion cannulae are intended for perfusion of the ascending aorta during short-term (< 6 hours) cardiopulmonary bypass procedures. Aortic cannulae in sizes 6 Fr. (2 mm) to 18 Fr. (6 mm) can be used in pediatric patient populations.
Product Codes/Lot Numbers:
Lot #s: 203876 207654 217024 226788,205724, 207655, 217025, 226938,205775, 208823, 217048, 227494,205868, 208893, 218185, 227886,205920, 208894, 218457, 228009,205921, 209901, 218539, 228259,205922, 209904, 219090, 228549,206369, 210110, 219212, 228558,206372, 210111, 219561, 229051,206373, 212032 ,220146 ,229054,206374, 212033 ,220151 ,229827,206768, 212034 ,220157 ,230690,206769, 212035 ,220802 ,230894,206770, 212258 ,220803 ,231105,206771, 212280 ,222841 ,231109,206772, 212959 ,222913 ,231111,206773, 213506 ,222914 ,231291,206774, 213914 ,222915 ,231485,206775, 214214 ,223174 ,232109,206776 ,214216 ,224233 ,232437,206777 ,214716 ,224235 ,234138,206778 ,214717 ,224662,207319 ,214961 ,224707,207320 ,215239 ,225306,207321 ,215495 ,225884,207322 ,216123 ,225885,207323 ,216196 ,226188,207324 ,216627 ,226596,207636 ,216628 ,226597,207638 ,216632, 226691
Official Source
Always verify recall information with the official FDA source:
View on FDA.govFDA Recall Number: Z-0420-2020
Related Recalls
due to complaints received for 3mm to 4mm section wire exposed/protruding from the outside of the cannula body.
due to complaints received for 3mm to 4mm section wire exposed/protruding from the outside of the cannula body.
due to complaints received for 3mm to 4mm section wire exposed/protruding from the outside of the cannula body.