TroClose 1200 - Product Usage: intended for use in a variety of gynecologic, general and urologic endoscopic procedures, to create and maintain a port of entry and to facilitate the delivery of absorbable sutures and anchors through soft tissues of the body during endoscopic / laparoscopic surgery. The trocar may be used with or without visualization for primary and secondary insertions. It is comprised of a single patient use, bladeless Obturator designed to allow penetration and positioning at the required site within the abdomen, and several single use Cannulas, which serve as working channels for the procedure. The Cannulas are pre-loaded with two synthetic absorbable sutures, each attached to a synthetic absorbable anchor. The deployment of the anchors and sutures is achieved by utilizing a mechanism within the Obturator. The Cannula is 115 mm long and is compatible for use with laparoscopic devices of 5 - 12 mm outer diameter.

Class I - Dangerous

What Should You Do?

  1. Check if you have this product:
    Catalog Number: GSTC1200 Lot Numbers: AS200009/3, Exp 14 FEB 2022 AS200012/4, Exp 23 MAR 2022
  2. Do not eat it: Even if it looks and smells fine, do not consume this product.
  3. Throw it away or return it: You can return the product to the store for a full refund.
  4. Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
  5. Report problems: Report any issues to the FDA's Safety Reporting Portal.

⚠️ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.

Recall Details

Company:
Gordian Surgical
Reason for Recall:
Endotoxin test results found above the acceptable levels in LAL test (above 20EU/device).
Classification:
Class I - Dangerous

Dangerous or defective products that predictably could cause serious health problems or death.

Status:
terminated

Product Information

Full Description:

TroClose 1200 - Product Usage: intended for use in a variety of gynecologic, general and urologic endoscopic procedures, to create and maintain a port of entry and to facilitate the delivery of absorbable sutures and anchors through soft tissues of the body during endoscopic / laparoscopic surgery. The trocar may be used with or without visualization for primary and secondary insertions. It is comprised of a single patient use, bladeless Obturator designed to allow penetration and positioning at the required site within the abdomen, and several single use Cannulas, which serve as working channels for the procedure. The Cannulas are pre-loaded with two synthetic absorbable sutures, each attached to a synthetic absorbable anchor. The deployment of the anchors and sutures is achieved by utilizing a mechanism within the Obturator. The Cannula is 115 mm long and is compatible for use with laparoscopic devices of 5 - 12 mm outer diameter.

Product Codes/Lot Numbers:

Catalog Number: GSTC1200 Lot Numbers: AS200009/3, Exp 14 FEB 2022 AS200012/4, Exp 23 MAR 2022

Official Source

Always verify recall information with the official FDA source:

View on FDA.gov

FDA Recall Number: Z-0398-2021