Ysio (model number 10281013 or 10281163) with Tube stand 3D V (model number 7042018 or 7042034), radiographic systems used for radiographic and tomographic exposures of the whole body.
Class I - DangerousWhat Should You Do?
- Check if you have this product: Serial Number 23071 22776 23623 23678 22787 23021 22848 22288 22960 23082 22501 23029 23163 23164 23518 23519 22517 23538 23097 22781 23147 22506 22634 22844 23427 23169 23529 22880 23699 22429 23640 22650 22737 22542 22176 22500 22350 22247 22347 22724 22725 22895 22833 22955 22058 23400 22847 22852 22367 22600 23650 23651 22705 22928 22609 23136 23133 23137 23556 22543 23474 22821 23517 23118 23410 22789 22208 22632 23022 23024 23132 23663 23149 22743 22851 22175 23602 23018 23019 22166 22170 22945 23476 22869 23726 23035 22431 22777 22859 22861 22824 22693 22757 22651 22171 22630 23619 22941 22957 22366 23098 22998 22427 23168 22729 23459 23625 23627 22748 23054 23063 23578 23177 22352 22353 22354 23597 22736 22618 22828 22458 22695 22644 23141 22211 23059 23079 23078 23167 23464 22184 22804 22392 22234 22235 22289 22795 23172 23173 22592 22271 22914
- Do not eat it: Even if it looks and smells fine, do not consume this product.
- Throw it away or return it: You can return the product to the store for a full refund.
- Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
- Report problems: Report any issues to the FDA's Safety Reporting Portal.
ā ļø Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.
Recall Details
- Company:
- Siemens Medical Solutions USA, Inc
- Reason for Recall:
- In rare cases of high clinical workload, the steel cables inside the lifting column of the overhead tube, which are designed to take the load, may rapture without triggering the safety lock. This could lead to overloading the safety rope, which is not designed for continuous load and ongoing movement under load. This may lead to mechanical fatigue and cause the arm to drop down unexpectedly during movement in vertical direction and during patient positioning.
- Classification:
- Class I - Dangerous
Dangerous or defective products that predictably could cause serious health problems or death.
- Status:
- terminated
Product Information
Full Description:
Ysio (model number 10281013 or 10281163) with Tube stand 3D V (model number 7042018 or 7042034), radiographic systems used for radiographic and tomographic exposures of the whole body.
Product Codes/Lot Numbers:
Serial Number 23071 22776 23623 23678 22787 23021 22848 22288 22960 23082 22501 23029 23163 23164 23518 23519 22517 23538 23097 22781 23147 22506 22634 22844 23427 23169 23529 22880 23699 22429 23640 22650 22737 22542 22176 22500 22350 22247 22347 22724 22725 22895 22833 22955 22058 23400 22847 22852 22367 22600 23650 23651 22705 22928 22609 23136 23133 23137 23556 22543 23474 22821 23517 23118 23410 22789 22208 22632 23022 23024 23132 23663 23149 22743 22851 22175 23602 23018 23019 22166 22170 22945 23476 22869 23726 23035 22431 22777 22859 22861 22824 22693 22757 22651 22171 22630 23619 22941 22957 22366 23098 22998 22427 23168 22729 23459 23625 23627 22748 23054 23063 23578 23177 22352 22353 22354 23597 22736 22618 22828 22458 22695 22644 23141 22211 23059 23079 23078 23167 23464 22184 22804 22392 22234 22235 22289 22795 23172 23173 22592 22271 22914
Distribution:
Nationwide distribution
Official Source
Always verify recall information with the official FDA source:
View on FDA.govFDA Recall Number: Z-0299-2019
Related Recalls
ARTIS Icono biplane, floor and ceiling.: ARTIS icono biplane Model 11327600. ARTIS icono ceiling Model 11328100. ARTIS icono floor Model 11327700. interventional fluoroscopic x-ray system
Siemens Medical Solutions USA
During patient examinations, the system may sporadically display a 0 x-ray dose administered to the patient. This behavior has only been observed during fluoroscopy and/or single-frame acquisitions. Despite the reported x-ray dose showing 0, an actual x-ray dose is applied to the patient.
ARTIS pheno, Model 10849000. interventional fluoroscopic x-ray system
Siemens Medical Solutions USA
During patient examinations, the system may sporadically display a 0 x-ray dose administered to the patient. This behavior has only been observed during fluoroscopy and/or single-frame acquisitions. Despite the reported x-ray dose showing 0, an actual x-ray dose is applied to the patient.
ARTIS Pheno VE30A and VE40A, Model 10849000
Siemens Medical Solutions USA
During 3D acquisitions, lighter and darker patient images may be captured, which may result in less accurate 3D reconstruction. The variation of brightness is a result of a constant unregulated medium dose and the angular change of patient diameter caused by rotational acquisition. This may result in unintentional low-dose radiation exposure to a patient.