Spectra System/Legacy Guided Surgery Handle Kit (Part Number: G-HK) Spectra System/Legacy Guided Surgery Handle Kit (Part Number: G-HK) allows clinicians to drill through a surgical guide to create an osteotomy for implant placement with the precision and accuracy as designed with treatment planning software. The G-HK consists of 4 guide handles with inserts attached on each end. Each insert has an opening that matches the diameter of our surgical drills. The insert portion of the guide handle fits intimately into the guide sleeve that is embedded into a surgical guide.
Class I - DangerousWhat Should You Do?
- Check if you have this product: Lot # 38665, 38825, 42562, 42649, 43810, 45014, 46950, 50165, 45018, 50165, 52360, 52987, 60376, 62435, 64245, 67044, 73431, 73729, 74772, 70293
- Do not eat it: Even if it looks and smells fine, do not consume this product.
- Throw it away or return it: You can return the product to the store for a full refund.
- Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
- Report problems: Report any issues to the FDA's Safety Reporting Portal.
โ ๏ธ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.
Recall Details
- Company:
- Implant Direct Sybron Manufacturing, LLC
- Reason for Recall:
- The Spectra System/Legacy Guided Surgery Handle Kit had guided handle inserts that were out of Implant Direct specifications, from the results of complaints submitted by clinicians regarding the 3.4mm guide insert that will not allow the 3.4 drill to pass through, since the diameter is too small. In addition, the 2.3mm guide was too large.
- Classification:
- Class I - Dangerous
Dangerous or defective products that predictably could cause serious health problems or death.
- Status:
- terminated
Product Information
Full Description:
Spectra System/Legacy Guided Surgery Handle Kit (Part Number: G-HK) Spectra System/Legacy Guided Surgery Handle Kit (Part Number: G-HK) allows clinicians to drill through a surgical guide to create an osteotomy for implant placement with the precision and accuracy as designed with treatment planning software. The G-HK consists of 4 guide handles with inserts attached on each end. Each insert has an opening that matches the diameter of our surgical drills. The insert portion of the guide handle fits intimately into the guide sleeve that is embedded into a surgical guide.
Product Codes/Lot Numbers:
Lot # 38665, 38825, 42562, 42649, 43810, 45014, 46950, 50165, 45018, 50165, 52360, 52987, 60376, 62435, 64245, 67044, 73431, 73729, 74772, 70293
Official Source
Always verify recall information with the official FDA source:
View on FDA.govFDA Recall Number: Z-0283-2018
Related Recalls
The Drill stop kit contains incorrect components.
LEGACY SMARTBASE, NE 3.0D 1MML, REF: 8730-81NE; LEGACY SMARTBASE, NE 3.0D 2MML, REF 8730-82NE; LEGACY SMARTBASE NARROW NE 3.5D, REF: 8735-80NNE; LEGACY SMARTBASE, NE 3.5D 2MML, REF: 8735-82NE LEGACY SMARTBASE NARROW NE 4.5D, REF: 8745-80NNE; LEGACY SMARTBASE. NE 4.5D, REF: 8745-82NE;
Implant Direct Sybron Manufacturing
Non-engaging abutments were distributed without FDA clearance; the performance characteristics have not yet been adequately established.
ImplantDirect, REF 834713, Legacy 2 Implant 4.7mmD x 13mmL, 4.5mmD Platform,
Implant Direct Sybron Manufacturing
Packaged dental implant contains a different size then the size declared on the labeling.