S-LIFT Extension Shims Extension shims are manufactured from grade 5 titanium and are curved, rectangular slabs which have four protrusions used for ratcheting. They come in straight and pointed varieties, either with or without a tab containing an additional bend. Extension shims are designed to slide down retractor blades, and are optional retractor components utilized during lumbar interbody fusion procedures. They are intended to manipulate tissue and prevent tissue from interfering inside the surgical field.
Class I - DangerousWhat Should You Do?
- Check if you have this product: Part Number/Lot Number: 11-50109 43092R; 11-50109 46415; 11-50109 CT12H013; 11 -50109-1 46415-1; 11-50110 43089; 11-50110 43089R; 11-50110 46416; 11-50110-1 46416-1
- Do not eat it: Even if it looks and smells fine, do not consume this product.
- Throw it away or return it: You can return the product to the store for a full refund.
- Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
- Report problems: Report any issues to the FDA's Safety Reporting Portal.
⚠️ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.
Recall Details
- Company:
- SpineFrontier, Inc.
- Reason for Recall:
- Fit variation among all lots of S-LIFT extension shims with corresponding retractor blades. The firm's investigation revealed that extension shims may not fit down all retractor blades.
- Classification:
- Class I - Dangerous
Dangerous or defective products that predictably could cause serious health problems or death.
- Status:
- terminated
Product Information
Full Description:
S-LIFT Extension Shims Extension shims are manufactured from grade 5 titanium and are curved, rectangular slabs which have four protrusions used for ratcheting. They come in straight and pointed varieties, either with or without a tab containing an additional bend. Extension shims are designed to slide down retractor blades, and are optional retractor components utilized during lumbar interbody fusion procedures. They are intended to manipulate tissue and prevent tissue from interfering inside the surgical field.
Product Codes/Lot Numbers:
Part Number/Lot Number: 11-50109 43092R; 11-50109 46415; 11-50109 CT12H013; 11 -50109-1 46415-1; 11-50110 43089; 11-50110 43089R; 11-50110 46416; 11-50110-1 46416-1
Official Source
Always verify recall information with the official FDA source:
View on FDA.govFDA Recall Number: Z-0274-2014
Related Recalls
A-CIFT SoloFuse Fixed Angle Driver, Model Number 13-32101-01 (Component Part Numbers 14-32107-01 and 14-32106)
SpineFrontier
There is a potential for the driver to bind up when attempting to advance the intervertebral body fixation screw.
The PedFuse Pedicle Screw Rod Caliper included with the MISquito Pedicle Screw System may be used incorrectly as the Surgical Technique does not adequately convey the intended use of the design.
A crack may develop in the handle to the Inline Persuader, which may progress if the user continues to use the affected instrument.