Centricity PACS-IW, software versions V3.7.x through 3.7.3.9 SP3; Radiological Image Processing System
Class I - DangerousWhat Should You Do?
- Check if you have this product: UDI/DI none, Installed Product ID #: 101792-1-Centricity PACS-IW-00558370, 4345-1-Centricity PACS-IW-00558548, 12830-1-Centricity PACS-IW-00558312, 4378-1-Centricity PACS-IW-00558498, 100663-1-Centricity PACS-IW-00558514, 100858-1-Centricity PACS-IW-00558426, 100702-1-Centricity PACS-IW-00558539, 4109-1-Centricity PACS-IW-00558389, 101625-1-Centricity PACS-IW-00558531, 4593-1-Centricity PACS-IW-00558488, 100009-1-Centricity PACS-IW-00558560, 100838-1-Centricity PACS-IW-00558532, 4300-1-Centricity PACS-IW-00558207, 4294-1-Centricity PACS-IW-00558379, 13039-1-Centricity PACS-IW-00558385, 13102-1-Centricity PACS-IW-00558512, 4694-1-Centricity PACS-IW-00558556, 101742-1-Centricity PACS-IW-00558470, 101883-1-Centricity PACS-IW-00558487, 9791-1-Centricity PACS-IW-00558418, 11764-1-Centricity PACS-IW-00558388, 101689-1-Centricity PACS-IW-00558326, 4744-1-Centricity PACS-IW-00558373, 4358-1-Centricity PACS-IW-00558564, 1402-7-Centricity PACS-IW-18957305, 1402-7-Centricity PACS-IW-19265438, 1402-7-Centricity PACS-IW-18166109, 1402-7-Centricity PACS-IW-18166110, 1402-2-Centricity PACS-IW-18984905, 1402-2-Centricity PACS-IW-18985934, 1402-2-Centricity PACS-IW-19031647, 1402-1-Centricity PACS-IW-17192703, 1402-1-Centricity PACS-IW-17192704, 1402-1-Centricity PACS-IW-00558291, 13095-1-Centricity PACS-IW-00558534, 4326-4-Centricity PACS-IW-00558105, 4352-1-Centricity PACS-IW-00558316, 4443-1-Centricity PACS-IW-00558167, 4374-1-Centricity PACS-IW-00558422, 4301-1-Centricity PACS-IW-00558525, 2387-1-Centricity PACS-IW-00558489, 4277-1-Centricity PACS-IW-00558474, 100802-1-Centricity PACS-IW-00558540, 101216-1-Centricity PACS-IW-00558356, 101193-1-Centricity PACS-IW-00558551, 101240-1-Centricity PACS-IW-00558425, 4661-1-Centricity PACS-IW-00558528, 3943-1-Centricity PACS-IW-00558501, 4361-1-Centricity PACS-IW-00558343, 12949-1-Centricity PACS-IW-00558442, 4276-1-Centricity PACS-IW-00558274, 4383-1-Centricity PACS-IW-00558533, 13233-3-Centricity PACS-IW-00558554, 12974-1-Centricity PACS-IW-00558300, 4393-1-Centricity PACS-IW-00558328, 4482-1-Centricity PACS-IW-00558281, 4389-1-Centricity PACS-IW-00558563, 100645-1-Centricity PACS-IW-14764451, 4573-1-Centricity PACS-IW-00558420, 4506-1-Centricity PACS-IW-00558345, AZ4030-Centricity PACS-IW-02336621, BA4080-Centricity PACS-IW-00038769, 707509-Centricity PACS-IW-01452391, 324462-Centricity PACS-IW-01431554, 613493-Centricity PACS-IW-02292544, 302144-Centricity PACS-IW-01421157, 246838-Centricity PACS-IW-01421153, 213537-Centricity PACS-IW-01431510, 319674-Centricity PACS-IW-01431535, 280801-Centricity PACS-IW-01431490, 320090-Centricity PACS-IW-01444604, 307319-Centricity PACS-IW-01444609, SiteID-Centricity PACS-IW-01572187, RMUE01-Centricity PACS-IW-00001801, StThomas-Centricity PACS-IW-01819447, HOLY-FAMILY-THODU-Centricity PACS-IW-01821493, WOCKHARDT-Centricity PACS-IW-01819449, SIMS-Centricity PACS-IW-01819453, MARTHANDAM-Centricity PACS-IW-01819446, CONTINENTAL-Centricity PACS-IW-01819443, A2513980-Centricity PACS-IW-00040355, KW1019-Centricity PACS-IW-00115173, KW1112-Centricity PACS-IW-00168151, KW1018-Centricity PACS-IW-01422962, KW1003-Centricity PACS-IW-01798078, KW1001-Centricity PACS-IW-00164288, SSH-Centricity PACS-IW-01288660, PL2997-Centricity PACS-IW-00038793, PL1803-Centricity PACS-IW-00038812, PL1825-Centricity PACS-IW-00038819, PL1006-Centricity PACS-IW-00038821, PL1822-Centricity PACS-IW-00038825, TBD-Centricity PACS-IW-01273193, RU1241-Centricity PACS-IW-01273216, RU1493-Centricity PACS-IW-01273220, TBD-Centricity PACS-IW-01273244, RU2420-Centricity PACS-IW-01273234, RU3262-Centricity PACS-IW-01273245, RU6248-Centricity PACS-IW-01273279, RU8052-Centricity PACS-IW-02337508, RU8071-Centricity PACS-IW-01273295, -Centricity PACS-IW-01273233, RU7576-Centricity PACS-IW-01273287, RU3880-Centricity PACS-IW-01273266, RU2580-Centricity PACS-IW-01273240, RU2527-Centricity PACS-IW-01273235, RU3382-Centricity PACS-IW-01273247, RU2878-Centricity PACS-IW-01273243, TBD-Centricity PACS-IW-01273306, TBD-Centricity PACS-IW-01273258, RU5499-Centricity PACS-IW-01273278, RU3680-Centricity PACS-IW-01273260, RU1279-Centricity PACS-IW-02337628, RU1469-Centricity PACS-IW-01273219, TBD-Centricity PACS-IW-01273200, RU8321-Centricity PACS-IW-01273303, RU1130-Centricity PACS-IW-01273210, RU7426-Centricity PACS-IW-01273284, RU3380-Centricity PACS-IW-01273246, TBD-Centricity PACS-IW-01273262, TBD-Centricity PACS-IW-01273224, RU8953-Centricity PACS-IW-01273311, RU2367-Centricity PACS-IW-01273232, RU1026-Centricity PACS-IW-01273195, TBD-Centricity PACS-IW-01273198, RU8036-Centricity PACS-IW-01273293, RU7564-Centricity PACS-IW-01273286, RU3476-Centricity PACS-IW-01273251, RU3610-Centricity PACS-IW-01273257, RU1028-Centricity PACS-IW-01273197, RU1022-Centricity PACS-IW-01273194, RU5442-Centricity PACS-IW-01273277, RU3883-Centricity PACS-IW-01273267, RU3467-Centricity PACS-IW-01273250, RU3663-Centricity PACS-IW-01273259, RU7905-Centricity PACS-IW-01273291, TBD-Centricity PACS-IW-01273256, TBD-Centricity PACS-IW-01273296, RU7838-Centricity PACS-01273289, TBD-Centricity PACS-IW-01273218, RU8607-Centricity PACS-IW-01273308, ZA2470-Centricity PACS-IW-00116572, ZA2352-Centricity PACS-IW-00116570, ZA2471-Centricity PACS-IW-00116573, ZA2351-Centricity PACS-IW-00116569, ZA2356-Centricity PACS-IW-00116576, ZA2355-Centricity PACS-IW-00116575, 14335625-Centricity PACS-IW-20614918, ONCOLOGY-Centricity PACS-IW-01288658
- Do not eat it: Even if it looks and smells fine, do not consume this product.
- Throw it away or return it: You can return the product to the store for a full refund.
- Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
- Report problems: Report any issues to the FDA's Safety Reporting Portal.
⚠️ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.
Recall Details
- Company:
- GE Healthcare
- Reason for Recall:
- GE HealthCare has become aware of an issue where images from two different patients may be contained in a single study, when stored in Centricity PACS-IW V3.7.x, Centricity PACS-IW with Universal Viewer V5.0 and Centricity Universal Viewer V6.0 with PACS-IW foundation.
- Classification:
- Class I - Dangerous
Dangerous or defective products that predictably could cause serious health problems or death.
- Status:
- ongoing
Product Information
Full Description:
Centricity PACS-IW, software versions V3.7.x through 3.7.3.9 SP3; Radiological Image Processing System
Product Codes/Lot Numbers:
UDI/DI none, Installed Product ID #: 101792-1-Centricity PACS-IW-00558370, 4345-1-Centricity PACS-IW-00558548, 12830-1-Centricity PACS-IW-00558312, 4378-1-Centricity PACS-IW-00558498, 100663-1-Centricity PACS-IW-00558514, 100858-1-Centricity PACS-IW-00558426, 100702-1-Centricity PACS-IW-00558539, 4109-1-Centricity PACS-IW-00558389, 101625-1-Centricity PACS-IW-00558531, 4593-1-Centricity PACS-IW-00558488, 100009-1-Centricity PACS-IW-00558560, 100838-1-Centricity PACS-IW-00558532, 4300-1-Centricity PACS-IW-00558207, 4294-1-Centricity PACS-IW-00558379, 13039-1-Centricity PACS-IW-00558385, 13102-1-Centricity PACS-IW-00558512, 4694-1-Centricity PACS-IW-00558556, 101742-1-Centricity PACS-IW-00558470, 101883-1-Centricity PACS-IW-00558487, 9791-1-Centricity PACS-IW-00558418, 11764-1-Centricity PACS-IW-00558388, 101689-1-Centricity PACS-IW-00558326, 4744-1-Centricity PACS-IW-00558373, 4358-1-Centricity PACS-IW-00558564, 1402-7-Centricity PACS-IW-18957305, 1402-7-Centricity PACS-IW-19265438, 1402-7-Centricity PACS-IW-18166109, 1402-7-Centricity PACS-IW-18166110, 1402-2-Centricity PACS-IW-18984905, 1402-2-Centricity PACS-IW-18985934, 1402-2-Centricity PACS-IW-19031647, 1402-1-Centricity PACS-IW-17192703, 1402-1-Centricity PACS-IW-17192704, 1402-1-Centricity PACS-IW-00558291, 13095-1-Centricity PACS-IW-00558534, 4326-4-Centricity PACS-IW-00558105, 4352-1-Centricity PACS-IW-00558316, 4443-1-Centricity PACS-IW-00558167, 4374-1-Centricity PACS-IW-00558422, 4301-1-Centricity PACS-IW-00558525, 2387-1-Centricity PACS-IW-00558489, 4277-1-Centricity PACS-IW-00558474, 100802-1-Centricity PACS-IW-00558540, 101216-1-Centricity PACS-IW-00558356, 101193-1-Centricity PACS-IW-00558551, 101240-1-Centricity PACS-IW-00558425, 4661-1-Centricity PACS-IW-00558528, 3943-1-Centricity PACS-IW-00558501, 4361-1-Centricity PACS-IW-00558343, 12949-1-Centricity PACS-IW-00558442, 4276-1-Centricity PACS-IW-00558274, 4383-1-Centricity PACS-IW-00558533, 13233-3-Centricity PACS-IW-00558554, 12974-1-Centricity PACS-IW-00558300, 4393-1-Centricity PACS-IW-00558328, 4482-1-Centricity PACS-IW-00558281, 4389-1-Centricity PACS-IW-00558563, 100645-1-Centricity PACS-IW-14764451, 4573-1-Centricity PACS-IW-00558420, 4506-1-Centricity PACS-IW-00558345, AZ4030-Centricity PACS-IW-02336621, BA4080-Centricity PACS-IW-00038769, 707509-Centricity PACS-IW-01452391, 324462-Centricity PACS-IW-01431554, 613493-Centricity PACS-IW-02292544, 302144-Centricity PACS-IW-01421157, 246838-Centricity PACS-IW-01421153, 213537-Centricity PACS-IW-01431510, 319674-Centricity PACS-IW-01431535, 280801-Centricity PACS-IW-01431490, 320090-Centricity PACS-IW-01444604, 307319-Centricity PACS-IW-01444609, SiteID-Centricity PACS-IW-01572187, RMUE01-Centricity PACS-IW-00001801, StThomas-Centricity PACS-IW-01819447, HOLY-FAMILY-THODU-Centricity PACS-IW-01821493, WOCKHARDT-Centricity PACS-IW-01819449, SIMS-Centricity PACS-IW-01819453, MARTHANDAM-Centricity PACS-IW-01819446, CONTINENTAL-Centricity PACS-IW-01819443, A2513980-Centricity PACS-IW-00040355, KW1019-Centricity PACS-IW-00115173, KW1112-Centricity PACS-IW-00168151, KW1018-Centricity PACS-IW-01422962, KW1003-Centricity PACS-IW-01798078, KW1001-Centricity PACS-IW-00164288, SSH-Centricity PACS-IW-01288660, PL2997-Centricity PACS-IW-00038793, PL1803-Centricity PACS-IW-00038812, PL1825-Centricity PACS-IW-00038819, PL1006-Centricity PACS-IW-00038821, PL1822-Centricity PACS-IW-00038825, TBD-Centricity PACS-IW-01273193, RU1241-Centricity PACS-IW-01273216, RU1493-Centricity PACS-IW-01273220, TBD-Centricity PACS-IW-01273244, RU2420-Centricity PACS-IW-01273234, RU3262-Centricity PACS-IW-01273245, RU6248-Centricity PACS-IW-01273279, RU8052-Centricity PACS-IW-02337508, RU8071-Centricity PACS-IW-01273295, -Centricity PACS-IW-01273233, RU7576-Centricity PACS-IW-01273287, RU3880-Centricity PACS-IW-01273266, RU2580-Centricity PACS-IW-01273240, RU2527-Centricity PACS-IW-01273235, RU3382-Centricity PACS-IW-01273247, RU2878-Centricity PACS-IW-01273243, TBD-Centricity PACS-IW-01273306, TBD-Centricity PACS-IW-01273258, RU5499-Centricity PACS-IW-01273278, RU3680-Centricity PACS-IW-01273260, RU1279-Centricity PACS-IW-02337628, RU1469-Centricity PACS-IW-01273219, TBD-Centricity PACS-IW-01273200, RU8321-Centricity PACS-IW-01273303, RU1130-Centricity PACS-IW-01273210, RU7426-Centricity PACS-IW-01273284, RU3380-Centricity PACS-IW-01273246, TBD-Centricity PACS-IW-01273262, TBD-Centricity PACS-IW-01273224, RU8953-Centricity PACS-IW-01273311, RU2367-Centricity PACS-IW-01273232, RU1026-Centricity PACS-IW-01273195, TBD-Centricity PACS-IW-01273198, RU8036-Centricity PACS-IW-01273293, RU7564-Centricity PACS-IW-01273286, RU3476-Centricity PACS-IW-01273251, RU3610-Centricity PACS-IW-01273257, RU1028-Centricity PACS-IW-01273197, RU1022-Centricity PACS-IW-01273194, RU5442-Centricity PACS-IW-01273277, RU3883-Centricity PACS-IW-01273267, RU3467-Centricity PACS-IW-01273250, RU3663-Centricity PACS-IW-01273259, RU7905-Centricity PACS-IW-01273291, TBD-Centricity PACS-IW-01273256, TBD-Centricity PACS-IW-01273296, RU7838-Centricity PACS-01273289, TBD-Centricity PACS-IW-01273218, RU8607-Centricity PACS-IW-01273308, ZA2470-Centricity PACS-IW-00116572, ZA2352-Centricity PACS-IW-00116570, ZA2471-Centricity PACS-IW-00116573, ZA2351-Centricity PACS-IW-00116569, ZA2356-Centricity PACS-IW-00116576, ZA2355-Centricity PACS-IW-00116575, 14335625-Centricity PACS-IW-20614918, ONCOLOGY-Centricity PACS-IW-01288658
Distribution:
Distributed in: US
Official Source
Always verify recall information with the official FDA source:
View on FDA.govFDA Recall Number: Z-0138-2024
Related Recalls
SIGNA Premier systems
GE Healthcare
Whole-Body MR scanners used to produce images of the inside of the human body to aid diagnosis of disease may have been manufactured/serviced with ferrous (steel) fittings instead of non-ferrous (brass) fittings on the magnet rear and if system is accessed to perform service while the magnet is ramped, the magnetic field could attract the ferrous fittings potentially resulting in personnel injury.
Under certain workflows, patient information shown in the viewer may not match the images displayed on Centricity Universal Viewer Zero Footprint Client (ZFP) with versions ZFP v6.0: SP11.6, SP11.6.0.1 and SP11.6.1 on systems with Patient Timeline installed,
There is a potential security vulnerability in Centricity Universal Viewer (UV), Centricity PACS-IW (PACS-IW), Centricity Radiology RA600 (RA600), & Centricity Cardiology CA1000 (CA1000) where the service login credentials are able to be identified which could allow a malicious actor with these credentials to access the system and potentially manipulate patient data.