Monode, Shortwave Accessory Model #: 02200002 Used in conjunction with the Intelect Shortwave Diathermy 100 and Intelect Shortwave Diathermy 400 units. For the clinical application of electromagnetic energy in the radio frequency of 27.12 megahertz to generate deep heat within body tissues.
Class I - DangerousWhat Should You Do?
- Check if you have this product: Model #: 02200002 All units received from the manufacture prior to the week of July 12, 2015
- Do not eat it: Even if it looks and smells fine, do not consume this product.
- Throw it away or return it: You can return the product to the store for a full refund.
- Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
- Report problems: Report any issues to the FDA's Safety Reporting Portal.
⚠️ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.
Recall Details
- Company:
- DJO, LLC
- Reason for Recall:
- Overheating and burning of the wire insulation inside the applicator.
- Classification:
- Class I - Dangerous
Dangerous or defective products that predictably could cause serious health problems or death.
- Status:
- terminated
Product Information
Full Description:
Monode, Shortwave Accessory Model #: 02200002 Used in conjunction with the Intelect Shortwave Diathermy 100 and Intelect Shortwave Diathermy 400 units. For the clinical application of electromagnetic energy in the radio frequency of 27.12 megahertz to generate deep heat within body tissues.
Product Codes/Lot Numbers:
Model #: 02200002 All units received from the manufacture prior to the week of July 12, 2015
Official Source
Always verify recall information with the official FDA source:
View on FDA.govFDA Recall Number: Z-0121-2016
Related Recalls
Due to broken connector which may result in a temporary interruption of prescribed cold therapy.
Due to broken connector which may result in a temporary interruption of prescribed cold therapy.
The IFU (Information for Use) on the wrap instructs the user to heat the hot and cold compression wrap in the microwave for 3 minutes, which may cause the wrap to leak or break at the seams and/or reach temperatures capable of causing a second degree burn.