Straumann Bone Level Tapered Implant 04.1 mm RC, SLActive¿ 8mm, Roxolid¿, Loxim Article Number: 021 .5308 Dental implants are intended for surgical placement in maxillary and/or mandibular arches to provide support for prosthetic restorations in edentulous or partially edentulous patients. Dental implants are for single-stage or two-stage surgery.
Class I - DangerousWhat Should You Do?
- Check if you have this product: Lot number: GY030 Exp. 2019-04
- Do not eat it: Even if it looks and smells fine, do not consume this product.
- Throw it away or return it: You can return the product to the store for a full refund.
- Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
- Report problems: Report any issues to the FDA's Safety Reporting Portal.
⚠️ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.
Recall Details
- Company:
- Straumann USA, LLC
- Reason for Recall:
- Assembled with Narrow Connect (NC) transfer piece instead of Regular Connect (RC)
- Classification:
- Class I - Dangerous
Dangerous or defective products that predictably could cause serious health problems or death.
- Status:
- terminated
Product Information
Full Description:
Straumann Bone Level Tapered Implant 04.1 mm RC, SLActive¿ 8mm, Roxolid¿, Loxim Article Number: 021 .5308 Dental implants are intended for surgical placement in maxillary and/or mandibular arches to provide support for prosthetic restorations in edentulous or partially edentulous patients. Dental implants are for single-stage or two-stage surgery.
Product Codes/Lot Numbers:
Lot number: GY030 Exp. 2019-04
Distribution:
Distributed in: US, FL, MA
Official Source
Always verify recall information with the official FDA source:
View on FDA.govFDA Recall Number: Z-0117-2015
Related Recalls
Straumann n!ce Zr, HT, Full-arch Restoration. Article 010.0158. Endosseous Dental Implant Abutments
Straumann USA
Includes an incorrect screw seat interface.
Straumann n!ce PMMA Full-arch Restoration. Screw-retained Bridge. Article 010.0304. Endosseous Dental Implant Abutments
Straumann USA
Includes an incorrect screw seat interface.
A material mix-up had occurred during the manufacturing of Straumann¿ Custom Abutments. More specifically, a raw material bar of TAN-material (SAP #701924 / Lot 7130439) was incorrectly identified as a Titanium Bar Ti Gr4 D (SAP #701922 / Lot 7130430). As a result, RC Titanium abutments were manufactured using the TAN Bar material on Mill-from-Bar Machine 396-06.