Automated Impella Controller (AIC), used for left heart support blood pump, labeled as the following with corresponding Product Codes: 1. Impella Controller, Packaged, AU; Product Code: 0042-0000-AU. 2. Impella Controller, Packaged, CA; Product Code: 0042-0000-CA. 3. Impella Controller, Packaged, EU; Product Code: 0042-0000-EU. 4. Impella Controller, Packaged, EU, Loaner; Product Code: 0042-0000-EU-L. 5. Impella Controller, Packaged, IN; Product Code: 0042-0000-IN. 6. Impella Controller, Packaged, JP; Product Code: 0042-0000-JP. 7. Impella Controller, Japan, Loaner; Product Code: 0042-0000-JP-L. 8. Impella Controller, Packaged, UK; Product Code: 0042-0000-UK. 9. Impella Controller, UK, Loaner; Product Code: 0042-0000-UK-L. 10. Impella Controller, Packaged, US; Product Code: 0042-0000-US. 11. Impella Controller, Packaged, US, Loaner; Product Code: 0042-0000-US-L. 12. Impella Optical Controller, Packaged, AU; Product Code: 0042-0010-AU. 13. Impella Optical Controller, Packaged, EU; Product Code: 0042-0010-EU. 14. Impella Optical Controller, EU, Loaner; Product Code: 0042-0010-EU-L. 15. Impella Optical Controller, Packaged, IN; Product Code: 0042-0010-IN. 16. Impella Optical Controller, Packaged, UK; Product Code: 0042-0010-UK. 17. Impella Optical Controller, UK, Loaner; Product Code: 0042-0010-UK-L. 18. Impella Optical Controller, Packaged, US; Product Code: 0042-0010-US. 19. Impella Optical Controller, US, Loaner; Product Code: 0042-0010-US-L. 20. Optical, AIC, Impella Connect, Pkgd, AU; Product Code: 0042-0040-AU. 21. Optical AIC w/Impella Connect,Pack'd, CA; Product Code: 0042-0040-CA. 22. AIC w/Remote Link, Pkgd, Cln Trl, US; Product Code: 0042-0040-CT. 23. AIC w/Remote Link, Pkgd, Cln Trl, US; Product Code: 0042-0040-CT-L. 24. Optical AIC w/Impella Connect,Pack'd, EU; Product Code: 0042-0040-EU. 25. Optical AIC w/Impella Connect,EU,Loaner; Product Code: 0042-0040-EU-L. 26. Optical AIC w/Impella Connect, Pkgd, JP; Product Code: 0042-0040-JP. 27. Optical AIC w/Impella Connect, Pkgd, JP; Product Code: 0042-0040-JP-L. 28. Optical, AIC, Impella Connect, Pkgd, UK; Product Code: 0042-0040-UK. 29. Optical, AIC, Impella Connect, Pkgd, US; Product Code: 0042-0040-US. 30. Optical AIC Impella Connect, US, Loaner; Product Code: 0042-0040-US-L. 31. Dbl optical, AIC Impella Connect, Phg US; Product Code: 1000201. 32. AIC w/Impella Connect for ECP; Product Code: 1000432.
Class I - DangerousWhat Should You Do?
- Check if you have this product: 1. Product Code: 0042-0000-AU; GTIN: 813502010886; All Serial Numbers. 2. Product Code: 0042-0000-CA; GTIN: 813502011272; All Serial Numbers. 3. Product Code: 0042-0000-EU; GTIN: 813502011289; All Serial Numbers. 4. Product Code: 0042-0000-EU-L; GTIN: 813502011289; All Serial Numbers. 5. Product Code: 0042-0000-IN; GTIN: 813502011418; All Serial Numbers. 6. Product Code: 0042-0000-JP; GTIN: 813502010428; All Serial Numbers. 7. Product Code: 0042-0000-JP-L; GTIN: 813502010428; All Serial Numbers. 8. Product Code: 0042-0000-UK; GTIN: 813502011296; All Serial Numbers. 9. Product Code: 0042-0000-UK-L; GTIN: 813502011296; All Serial Numbers. 10. Product Code: 0042-0000-US; GTIN: 813502010022; All Serial Numbers. 11. Product Code: 0042-0000-US-L; GTIN: 813502010022; All Serial Numbers. 12. Product Code: 0042-0010-AU; GTIN: 813502010930; All Serial Numbers. 13. Product Code: 0042-0010-EU; GTIN: 813502010961; All Serial Numbers. 14. Product Code: 0042-0010-EU-L; GTIN: 813502010961; All Serial Numbers. 15. Product Code: 0042-0010-IN; GTIN: 813502011425; All Serial Numbers. 16. Product Code: 0042-0010-UK; GTIN: 813502010978; All Serial Numbers. 17. Product Code: 0042-0010-UK-L; GTIN: 813502010978; All Serial Numbers. 18. Product Code: 0042-0010-US; GTIN: 813502010985; All Serial Numbers. 19. Product Code: 0042-0010-US-L; GTIN: 813502010985; All Serial Numbers. 20. Product Code: 0042-0040-AU; GTIN: 813502012972; All Serial Numbers. 21. Product Code: 0042-0040-CA; GTIN: 813502012958; All Serial Numbers. 22. Product Code: 0042-0040-CT; GTIN: 813502011722; All Serial Numbers. 23. Product Code: 0042-0040-CT-L; GTIN: 813502011722; All Serial Numbers. 24. Product Code: 0042-0040-EU; GTIN: 813502012217; All Serial Numbers. 25. Product Code: 0042-0040-EU-L; GTIN: 813502012217; All Serial Numbers. 26. Product Code: 0042-0040-JP; GTIN: 813502011814; All Serial Numbers. 27. Product Code: 0042-0040-JP-L; GTIN: 813502011814; All Serial Numbers. 28. Product Code: 0042-0040-UK; GTIN: 813502012484; All Serial Numbers. 29. Product Code: 0042-0040-US; GTIN: 813502011401; All Serial Numbers. 30. Product Code: 0042-0040-US-L; GTIN: 813502011401; All Serial Numbers. 31. Product Code: 1000201; GTIN: 813502010442; All Serial Numbers. 32. Product Code: 1000432; GTIN: 813502013030; All Serial Numbers.
- Do not eat it: Even if it looks and smells fine, do not consume this product.
- Throw it away or return it: You can return the product to the store for a full refund.
- Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
- Report problems: Report any issues to the FDA's Safety Reporting Portal.
⚠️ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.
Recall Details
- Company:
- Abiomed, Inc.
- Reason for Recall:
- Potential cybersecurity vulnerabilities related to the operating system in the Automated Impella Controller (AIC).
- Classification:
- Class I - Dangerous
Dangerous or defective products that predictably could cause serious health problems or death.
- Status:
- ongoing
Product Information
Full Description:
Automated Impella Controller (AIC), used for left heart support blood pump, labeled as the following with corresponding Product Codes: 1. Impella Controller, Packaged, AU; Product Code: 0042-0000-AU. 2. Impella Controller, Packaged, CA; Product Code: 0042-0000-CA. 3. Impella Controller, Packaged, EU; Product Code: 0042-0000-EU. 4. Impella Controller, Packaged, EU, Loaner; Product Code: 0042-0000-EU-L. 5. Impella Controller, Packaged, IN; Product Code: 0042-0000-IN. 6. Impella Controller, Packaged, JP; Product Code: 0042-0000-JP. 7. Impella Controller, Japan, Loaner; Product Code: 0042-0000-JP-L. 8. Impella Controller, Packaged, UK; Product Code: 0042-0000-UK. 9. Impella Controller, UK, Loaner; Product Code: 0042-0000-UK-L. 10. Impella Controller, Packaged, US; Product Code: 0042-0000-US. 11. Impella Controller, Packaged, US, Loaner; Product Code: 0042-0000-US-L. 12. Impella Optical Controller, Packaged, AU; Product Code: 0042-0010-AU. 13. Impella Optical Controller, Packaged, EU; Product Code: 0042-0010-EU. 14. Impella Optical Controller, EU, Loaner; Product Code: 0042-0010-EU-L. 15. Impella Optical Controller, Packaged, IN; Product Code: 0042-0010-IN. 16. Impella Optical Controller, Packaged, UK; Product Code: 0042-0010-UK. 17. Impella Optical Controller, UK, Loaner; Product Code: 0042-0010-UK-L. 18. Impella Optical Controller, Packaged, US; Product Code: 0042-0010-US. 19. Impella Optical Controller, US, Loaner; Product Code: 0042-0010-US-L. 20. Optical, AIC, Impella Connect, Pkgd, AU; Product Code: 0042-0040-AU. 21. Optical AIC w/Impella Connect,Pack'd, CA; Product Code: 0042-0040-CA. 22. AIC w/Remote Link, Pkgd, Cln Trl, US; Product Code: 0042-0040-CT. 23. AIC w/Remote Link, Pkgd, Cln Trl, US; Product Code: 0042-0040-CT-L. 24. Optical AIC w/Impella Connect,Pack'd, EU; Product Code: 0042-0040-EU. 25. Optical AIC w/Impella Connect,EU,Loaner; Product Code: 0042-0040-EU-L. 26. Optical AIC w/Impella Connect, Pkgd, JP; Product Code: 0042-0040-JP. 27. Optical AIC w/Impella Connect, Pkgd, JP; Product Code: 0042-0040-JP-L. 28. Optical, AIC, Impella Connect, Pkgd, UK; Product Code: 0042-0040-UK. 29. Optical, AIC, Impella Connect, Pkgd, US; Product Code: 0042-0040-US. 30. Optical AIC Impella Connect, US, Loaner; Product Code: 0042-0040-US-L. 31. Dbl optical, AIC Impella Connect, Phg US; Product Code: 1000201. 32. AIC w/Impella Connect for ECP; Product Code: 1000432.
Product Codes/Lot Numbers:
1. Product Code: 0042-0000-AU; GTIN: 813502010886; All Serial Numbers. 2. Product Code: 0042-0000-CA; GTIN: 813502011272; All Serial Numbers. 3. Product Code: 0042-0000-EU; GTIN: 813502011289; All Serial Numbers. 4. Product Code: 0042-0000-EU-L; GTIN: 813502011289; All Serial Numbers. 5. Product Code: 0042-0000-IN; GTIN: 813502011418; All Serial Numbers. 6. Product Code: 0042-0000-JP; GTIN: 813502010428; All Serial Numbers. 7. Product Code: 0042-0000-JP-L; GTIN: 813502010428; All Serial Numbers. 8. Product Code: 0042-0000-UK; GTIN: 813502011296; All Serial Numbers. 9. Product Code: 0042-0000-UK-L; GTIN: 813502011296; All Serial Numbers. 10. Product Code: 0042-0000-US; GTIN: 813502010022; All Serial Numbers. 11. Product Code: 0042-0000-US-L; GTIN: 813502010022; All Serial Numbers. 12. Product Code: 0042-0010-AU; GTIN: 813502010930; All Serial Numbers. 13. Product Code: 0042-0010-EU; GTIN: 813502010961; All Serial Numbers. 14. Product Code: 0042-0010-EU-L; GTIN: 813502010961; All Serial Numbers. 15. Product Code: 0042-0010-IN; GTIN: 813502011425; All Serial Numbers. 16. Product Code: 0042-0010-UK; GTIN: 813502010978; All Serial Numbers. 17. Product Code: 0042-0010-UK-L; GTIN: 813502010978; All Serial Numbers. 18. Product Code: 0042-0010-US; GTIN: 813502010985; All Serial Numbers. 19. Product Code: 0042-0010-US-L; GTIN: 813502010985; All Serial Numbers. 20. Product Code: 0042-0040-AU; GTIN: 813502012972; All Serial Numbers. 21. Product Code: 0042-0040-CA; GTIN: 813502012958; All Serial Numbers. 22. Product Code: 0042-0040-CT; GTIN: 813502011722; All Serial Numbers. 23. Product Code: 0042-0040-CT-L; GTIN: 813502011722; All Serial Numbers. 24. Product Code: 0042-0040-EU; GTIN: 813502012217; All Serial Numbers. 25. Product Code: 0042-0040-EU-L; GTIN: 813502012217; All Serial Numbers. 26. Product Code: 0042-0040-JP; GTIN: 813502011814; All Serial Numbers. 27. Product Code: 0042-0040-JP-L; GTIN: 813502011814; All Serial Numbers. 28. Product Code: 0042-0040-UK; GTIN: 813502012484; All Serial Numbers. 29. Product Code: 0042-0040-US; GTIN: 813502011401; All Serial Numbers. 30. Product Code: 0042-0040-US-L; GTIN: 813502011401; All Serial Numbers. 31. Product Code: 1000201; GTIN: 813502010442; All Serial Numbers. 32. Product Code: 1000432; GTIN: 813502013030; All Serial Numbers.
Official Source
Always verify recall information with the official FDA source:
View on FDA.govFDA Recall Number: Z-0069-2026
Related Recalls
Exposure to the low purge pressure occurrence may result in persistent low purge pressure alarms and, in some cases, interruption or loss of mechanical circulatory support.
Retrospective submission for following issues identified: 1. Alarm failures, power-path faults, electrical-short risks, and inaccurate motor-current sensing were identified in certain AIC consoles. 2. There is improper alignment between the purge cassette and the motor drive in the AIC. This can result in a piston block event and lead to the inability to complete priming of the purge system, requiring the user to switch to backup AIC console.
Potential that the "Purge System Blocked" alarm display on the Automated Impella Controller (AIC) could be delayed when using first generation Impella 5.5 (0550-0008*) pumps.