TORQ Sternal Closure Device. The common name is TWISTER, WIRE. The model number is TQ01A. The Catalog numbers are: 17-00001: TORQ Sternal Closure Device Shipping Carton (6-10 packs), Sterile and, 15-00001 (or 17-00002): TORQ Sternal Closure Device 10-pack - Sterile. The device is supplied double-pouched, inside a shelf box containing 10 devices each. Shelf boxes are shipped to customers in either a small shipping carton containing one (1) shelf box (for a total of 10 devices), or large shipping carton containing six (6) shelf boxes (for a total of 6 x 10 = 60 devices). This product is used to close the sternal wires during cardiac surgery, and it is not an implantable device. The TORQ Sternal Closure device is used during sternal closure to tension and twist standard stainless steel surgical sutures of USP size 6 or 7 (metric size 8.0 or 9.0). The TORQ device is designed for use as a standard surgical suture wire twister for sternal closure. (Surgical sutures are not provided with the device.) The TORQ device is disposable, single-use, non-implantable and supplied sterile.

Class I - Dangerous

What Should You Do?

  1. Check if you have this product:
    Lot No. 062711. Expiry date is June 2014.
  2. Do not eat it: Even if it looks and smells fine, do not consume this product.
  3. Throw it away or return it: You can return the product to the store for a full refund.
  4. Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
  5. Report problems: Report any issues to the FDA's Safety Reporting Portal.

⚠️ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.

Recall Details

Company:
Kardium
Reason for Recall:
The TORQ Sternal Closure Device, Lot 062711, is being recalled due to probability one of the metal parts may be dislodged during use.
Classification:
Class I - Dangerous

Dangerous or defective products that predictably could cause serious health problems or death.

Status:
terminated

Product Information

Full Description:

TORQ Sternal Closure Device. The common name is TWISTER, WIRE. The model number is TQ01A. The Catalog numbers are: 17-00001: TORQ Sternal Closure Device Shipping Carton (6-10 packs), Sterile and, 15-00001 (or 17-00002): TORQ Sternal Closure Device 10-pack - Sterile. The device is supplied double-pouched, inside a shelf box containing 10 devices each. Shelf boxes are shipped to customers in either a small shipping carton containing one (1) shelf box (for a total of 10 devices), or large shipping carton containing six (6) shelf boxes (for a total of 6 x 10 = 60 devices). This product is used to close the sternal wires during cardiac surgery, and it is not an implantable device. The TORQ Sternal Closure device is used during sternal closure to tension and twist standard stainless steel surgical sutures of USP size 6 or 7 (metric size 8.0 or 9.0). The TORQ device is designed for use as a standard surgical suture wire twister for sternal closure. (Surgical sutures are not provided with the device.) The TORQ device is disposable, single-use, non-implantable and supplied sterile.

Product Codes/Lot Numbers:

Lot No. 062711. Expiry date is June 2014.

Official Source

Always verify recall information with the official FDA source:

View on FDA.gov

FDA Recall Number: Z-0054-2013