Dr. J's Smart Gourmet SalsaMedium, 15 oz., UPC: 793573939166 (Medium).
Class I - DangerousWhat Should You Do?
- Check if you have this product: USE THRU dates from 10/29 (2014) to 2/4 (2015)
- Do not eat it: Even if it looks and smells fine, do not consume this product.
- Throw it away or return it: You can return the product to the store for a full refund.
- Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
- Report problems: Report any issues to the FDA's Safety Reporting Portal.
⚠️ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.
Recall Details
- Company:
- Condies Foods, Inc
- Reason for Recall:
- Condies Foods, Inc. is recalling Condies brand Bold and Zesty salsa and Dr. J's brand Mild and Medium salsas because they contain the recalled spice cumin, which may contain undeclared peanut protein.
- Classification:
- Class I - Dangerous
Dangerous or defective products that predictably could cause serious health problems or death.
- Status:
- terminated
Product Information
Full Description:
Dr. J's Smart Gourmet SalsaMedium, 15 oz., UPC: 793573939166 (Medium).
Product Codes/Lot Numbers:
USE THRU dates from 10/29 (2014) to 2/4 (2015)
Distribution:
Distributed in: VA
Official Source
Always verify recall information with the official FDA source:
View on FDA.govFDA Recall Number: F-1205-2015
Related Recalls
Class I - Dangerous
Undeclared SOY allergen. Wrong ingredient purchased and used.
Class I - Dangerous
Undeclared SOY allergen. Wrong ingredient purchased and used.
Class I - Dangerous
Condies Foods is recalling Veggie Cups due to undeclared milk and egg.