Gas Boilers Recall/Repair by Weil-McLain

Class II - Moderate

What Should You Do?

  1. Check if you have this product:
    ;
  2. Do not eat it: Even if it looks and smells fine, do not consume this product.
  3. Throw it away or return it: You can return the product to the store for a full refund.
  4. Report problems: Report any issues to the FDA's Safety Reporting Portal.

Recall Details

Company:
White-Rodgers
Reason for Recall:
Carbon Monoxide (CO)
Classification:
Class II - Moderate

Products that might cause a temporary health problem, or pose a slight threat of a serious nature.

Status:
ongoing
Hazard:
Carbon Monoxide (CO)

Product Information

Full Description:

Gas Boilers Recall/Repair by Weil-McLain NEWS from CPSC U.S. Consumer Product Safety Commission Office of Information and Public Affairs Washington, DC 20207 FOR IMMEDIATE RELEASE Originally issued May 11, 1998, Last Revised November 23, 2005 Release # 98-107 Company Phone Number: (219) 879-6561 CPSC Consumer Hotline: (800) 638-2772 CPSC Media Contact: Mark Ross, (301) 504-7076 Note: telephone number change CPSC, Weil-McLain Announce Recall to Repair Gas Boilers WASHINGTON, D.C.- In cooperation with the U.S. Consumer Product Safety Commission (CPSC), Weil-McLain, of Michigan City, Ind., is recalling 8,500 Weil-McLain gas boilers for field adjustment of the gas control valve. These boilers' gas control valves, made by White-Rodgers, could have gas pressure settings that are too high. Incorrect gas pressure can cause the boiler to produce dangerous carbon monoxide, which can then leak, causing serious injury or death. Weil-McLain has received three reports of carbon monoxide detectors alarming due to the release of carbon monoxide from these boilers. No injuries or deaths have been reported. The Weil-McLain model GV gas boilers subject to this recall are equipped with certain White-Rodgers model 36C98-303 gas control valves with date codes 9621 through 9723. The date code and model number can be found on the unit's gas control valve, which is located at the front and center section of the boiler under the jacket. Also, all Weil-McLain GV boilers located at elevations more than 7,000 feet above sea level are being recalled. These boilers have "WEIL-McLAIN GOLD GV" written on the boiler jacket. Heating and cooling companies and contractors sold these boilers nationwide from June 1996 to November 1997 for about $1,500 to $3,000. Approximately 1,000 GV boilers were installed from June 1990 to January 1998 at locations above 7,000 feet elevation. Consumers should immediately check to see if they have a Weil-McLain GV boiler affected by this recall. For assistance in checking the boiler's gas valve model and date code, or for other additional information, consumers should call Weil-McLain at (219) 879-6561. If a consumer has an affected boiler, Weil-McLain will arrange for a free adjustment of the gas control valves' pressure setting.

Product Codes/Lot Numbers:

;

Official Source

Always verify recall information with the official CPSC source:

View on CPSC.gov

CPSC Recall Number: 98107