Double Climber Slide playground equipment
Class II - ModerateWhat Should You Do?
- Check if you have this product: ; ; ;
- Do not eat it: Even if it looks and smells fine, do not consume this product.
- Throw it away or return it: You can return the product to the store for a full refund.
- Report problems: Report any issues to the FDA's Safety Reporting Portal.
Recall Details
- Company:
- Pixieland
- Reason for Recall:
- Entrapment
- Classification:
- Class II - Moderate
Products that might cause a temporary health problem, or pose a slight threat of a serious nature.
- Status:
- ongoing
- Hazard:
- Entrapment
Product Information
Full Description:
Playground Equipments Repaired by Pixieland NEWS from CPSC U.S. Consumer Product Safety Commission Office of Information and Public Affairs Washington, DC 20207 Note: Firm is out of business. Do not use these products. Please discard or destroy these products. FOR IMMEDIATE RELEASE Originally issued December 5, 1983; Revised July 10, 2001 Release # 83-062 Pixieland To Repair Potentially Hazardous Playground Equipment Washington, D.C.-- In cooperation with the U.S. Consumer Product Safety Commission, Pixieland, Incorporated, Swainsboro I Georgia, today announced a voluntary repair program on five different models of its metal playground equipment which may present head entrapment hazards to children. The products involved are the Double Climber Slide, Single Climber Slide, Toddler Climber, Fence Climber and Rainbow Climber. The five models of metal playground equipment, which range in cost from approximately $85 to $450, are intended for use by pre-school children, and are sold to day care centers, child care centers and other similar facilities. The spacing between some of the rungs on these five models pose a potential entrapment hazard because they are wide enough to allow a child's body to pass all the way through, but are too narrow for the head to follow. Consequently, a child could be hung, with his head trapped between the rungs and his feet off the ground. This could result in head injuries, neck injuries, or strangulation. All spacings ranging from 4.5 inches to 7.5 inches represent potential entrapment hazards. The Commission has investigated three incidents in which children's heads became entrapped between the rungs on these playground structures. One victim received contusions and abrasions to the neck and head, while another victim had to be resuscitated because his breathing and pulse had been stopped. Pixieland has been manufacturing these playground structures since 1978, with distribution to 21 states east of the Rockies. In 1978, the firm began to redesign this equipment to eliminate the potential head entrapment hazard. However, some of these units still have spacing between the rungs which are in the potential entrapment range of 4.5 to 7.5 inches. The Double Climber Slide, Single Climber Slide, and Rainbow Climber all are rainbow-shaped with apex approximately 4' from the ground. Each is approximately 4'4" wide and 15' to 16' in length. The Single Climber and Double Climber Slides have one and two sliding boards respectively, while the Rainbow Climber has no slide. The Toddler Climber is 3' high 3' wide, and 4' long, while the Fence Climber is similar in design but measures 4' high, 4' wide, and 6' long. A sticker label with the Pixieland name and address may be found on some of these structures. All day care centers, child care centers, etc., are urged to determine whether they have any of the five models of playground equipment. If they do, the spacings between all rungs should be measured. If any spacing measures from 4.5 inches to 7.5 inches, discontinue use of the equipment immediately. Firm is out of Business. Further information on this playground equipment can be obtained by calling the Commission's toll-free Hotline at 800-63S-CPSC. The teletypewriter number for the hearing impaired is (301) 595-7054.
Product Codes/Lot Numbers:
; ; ;
Official Source
Always verify recall information with the official CPSC source:
View on CPSC.govCPSC Recall Number: 83062