SBGA-34 Audible Fire Alarm Base

Class I - Dangerous

What Should You Do?

  1. Check if you have this product:
    (About 9,000)
  2. Do not eat it: Even if it looks and smells fine, do not consume this product.
  3. Throw it away or return it: You can return the product to the store for a full refund.
  4. Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
  5. Report problems: Report any issues to the FDA's Safety Reporting Portal.

⚠️ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.

Recall Details

Company:
Beijing Siemens Cerberus Electronics Ltd., of China
Reason for Recall:
The fire alarm base can fail to sound an alarm, posing a risk of personal injury and property damage.
Classification:
Class I - Dangerous

Dangerous or defective products that predictably could cause serious health problems or death.

Status:
ongoing
Hazard:
The fire alarm base can fail to sound an alarm, posing a risk of personal injury and property damage.
Remedy:
Consumers should immediately contact Siemens to schedule a free inspection and replacement of the recalled audible base.

Product Images

SBGA-34 Audible Fire Alarm BaseSBGA-34 Audible Fire Alarm Base

Product Information

Full Description:

This recall involves the SBGA-34 audible base that is affixed to ceiling-mounted smoke detectors in order to sound an alarm when the fire alarm system is activated. The audible base has part number S54370-F13 and date codes 0113 through 2314 in a WWYY format printed on a white label on the back of the unit part affixed to the wall. "MODEL SBGA-34" is printed on a blue label also affixed to the back of the device. The base is off-white and measures about 6 inches in diameter. The audible base is used with the following fire detectors: • Cerberus PRO models (HI921, OOHC941, OOH941, OH921, OP921) • Desigo Fire Safety models (FDOOTC441, FDOOT441, FDO421, FDOT421, FDT421) • H-Series (HFP-11, HFPT-11, HFPO-11) • Faraday 87XX-Series, models (8713, 8712, 8710) The audible base and fire detectors are used with the following alarm systems: • Siemens model FireFinder® XLS via DLC 6312 Device Loop Card • Siemens model FS -250 • Desigo model FC2005, (50-point panel) • Desigo model FC2025, (252-point system) • Desigo model FC2050, (504-point system) • Cerberus PRO FC901, (50-point panel • Cerberus PRO FC922, (252-point system) • Cerberus PRO FC924, (504-point system) • Faraday models MPC-600 and MPC-7000

Product Codes/Lot Numbers:

(About 9,000)

Official Source

Always verify recall information with the official CPSC source:

View on CPSC.gov

CPSC Recall Number: 14278