Gas Furnaces

Class I - Dangerous

What Should You Do?

  1. Check if you have this product:
    (About 226,000)
  2. Do not eat it: Even if it looks and smells fine, do not consume this product.
  3. Throw it away or return it: You can return the product to the store for a full refund.
  4. Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
  5. Report problems: Report any issues to the FDA's Safety Reporting Portal.

⚠️ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.

Recall Details

Company:
The Unitary Products Group (UPG) of York International Corp., of York, Pa.
Reason for Recall:
These furnaces can overheat, causing heat-exchanger cracking, burn-through and, in extreme cases, furnace wrapper burn-through. This can lead to heating and possible burning of the drywall and other combustibles adjacent to the furnace, which poses a fire and smoke hazard to consumers.
Classification:
Class I - Dangerous

Dangerous or defective products that predictably could cause serious health problems or death.

Status:
ongoing
Hazard:
These furnaces can overheat, causing heat-exchanger cracking, burn-through and, in extreme cases, furnace wrapper burn-through. This can lead to heating and possible burning of the drywall and other combustibles adjacent to the furnace, which poses a fire and smoke hazard to consumers.
Remedy:
Consumers should not use the heating function of these furnaces until it has been inspected and repaired. Consumers should contact UPG to schedule a free inspection and repair of any furnace involved in the recall.

Product Images

Gas FurnacesGas Furnaces

Product Information

Full Description:

The recall involves Coleman, Coleman Evcon and Red T brand furnaces. The furnaces are a silver color with white access panels. The "Coleman," "Coleman Evcon" and "Red T" brand names are located on the middle of the front access panel. These model furnaces with model numbers listed below are included in the recall: DGAM075BDD DGAM075BDE DGAM075BDF DGAT070BDD DGAT070BDE DGAT070BDF DGAT075BDD DGAT075BDE DGAT075BDF DLAS075BDD DLAS075BDE DLAS075BDF The model number is written on a nameplate, found by removing both front access panels. The nameplate is found mounted on the left inside surface behind the lower panel.

Product Codes/Lot Numbers:

(About 226,000)

Official Source

Always verify recall information with the official CPSC source:

View on CPSC.gov

CPSC Recall Number: 05047