Recall Details

Company:
e4L Inc., of Encino, Calif.
Reason for Recall:
The product's design allows consumers to light the grill at an air intake tube, instead of at the burner. Though the grill appears to function normally, gas inside the air intake tube ignites. The tube can reach temperatures of up to 750 degrees Fahrenheit and present a burn hazard to consumers. In grills manufactured before August 1998, the heat produced by lighting the grill at the air intake tube damaged the plastic support piece, and caused the grill to fall to the ground. When it collapses, flames from the grill can burn nearby consumers and ignite surrounding combustibles.
Classification:
Class II - Moderate

Products that might cause a temporary health problem, or pose a slight threat of a serious nature.

Status:
ongoing
Hazard:
The product's design allows consumers to light the grill at an air intake tube, instead of at the burner. Though the grill appears to function normally, gas inside the air intake tube ignites. The tube can reach temperatures of up to 750 degrees Fahrenheit and present a burn hazard to consumers. In grills manufactured before August 1998, the heat produced by lighting the grill at the air intake tube damaged the plastic support piece, and caused the grill to fall to the ground. When it collapses, flames from the grill can burn nearby consumers and ignite surrounding combustibles.
Remedy:
CPSC urges consumers to stop using these grills immediately. Consumers who purchased Red Devil gas grills from BJ's Wholesale Club Stores can return them to the local BJ's Wholesale Club for a refund.

Product Images

Red Devil gas grills

Product Information

Full Description:

These red metal gas grills have a tripod stand. They have a logo on the label of the lid and grill base, showing a devil cooking at a grill with the writing "Red Devil." The lid also reads "The Portable Outdoor Kitchen." Components sold with the grill include a heat plate, an oversized skillet with handles, a table-safe serving trivet, and carrying totes.

Product Codes/Lot Numbers:

(About 2,800)

Official Source

Always verify recall information with the official CPSC source:

View on CPSC.gov

CPSC Recall Number: 03535

Related Recalls

Red Devil Gas Grills

e4L Inc., of Encino, Calif.

Class II - Moderate

The product's design allows consumers to light the grill at an air intake tube, instead of at the burner. Though the grill appears to function normally, gas inside the air intake tube ignites. The tube can reach temperatures of up to 750 degrees Fahrenheit and present a burn hazard to consumers.

Oct 8, 2002 Furniture Nationwide View Details →