S.I.T. Gas Temperature Controls on GSW Water Heaters
Class II - Moderate 🏠 Consumer Products
Recalled: July 2, 2003 GSW Industries Inc., of Fergus, Ontario, Canada Home & Garden
Nationwide
What Should You Do?
- Check if you have this product: (13,000 (In addition, 140,000 units were sold in Canada))
- Do not eat it: Even if it looks and smells fine, do not consume this product.
- Throw it away or return it: You can return the product to the store for a full refund.
- Report problems: Report any issues to the FDA's Safety Reporting Portal.
Recall Details
- Company:
- GSW Industries Inc., of Fergus, Ontario, Canada
- Reason for Recall:
- A potential burn hazard from ignition flashback or an increase in tank water temperature.
- Classification:
- Class II - Moderate
Products that might cause a temporary health problem, or pose a slight threat of a serious nature.
- Status:
- ongoing
- Hazard:
- A potential burn hazard from ignition flashback or an increase in tank water temperature.
- Remedy:
- When installing a GSW water heater with a SIT AC4 gas control valve in the identified group, or re-lighting the pilot light, the following instructions must be complied with: 1 - Make sure that the water heater contains cool water prior to lighting the pilot by opening a hot water faucet near your water heater and allowing the water to run for five minutes. Close the faucet. 2 - Turn the gas/temperature control knob clockwise to the maximum (VERY HOT) setting, and then slowly turn the knob back counterclockwise to the PILOT position, indicated by the yellow button. Listen for the main valve to close- this would be a popping or snapping sound. This sound is different from the clicking sound that the knob makes as you turn it. 3 - If you hear the popping sound then the valve is working properly. You should then read and follow the "Installation and Operating Instructions". If you do not hear the popping sound then do not attempt to light the pilot and replace the valve. 4 - If the unit has been stored or is being installed in a cold environment and the main valve does not close before the knob is turned back to the PILOT position, the gas control valve must be warmed up to a temperature above 32 degrees F or 0 degrees C. Once warmed up, repeat the procedure above. If the gas control valve does not close (popping sound), replace the valve. If the water is too hot or if the temperature and pressure valve opens, turn down the temperature using the temperature control. If the water remains too hot or the temperature and pressure relief valve continues to open, then replace the valve.
Product Images

Product Information
Full Description:
This recall involves GSW water heaters with S.I.T. model 650 AC4 gas/temperature controls. The temperature control knobs on GSW propane water heaters are red and the control knobs on GSW natural gas water heaters are blue. The controls can be found on GSW Water Heaters with serial numbers ranging from 0202694162 to 0304507825.
Product Codes/Lot Numbers:
(13,000 (In addition, 140,000 units were sold in Canada))