The action is being initiated due to internal testing which identified a possibility for transducers to exceed the acoustic output power (AOP) values defined . The transit voltage values based on PW Doppler are calculated normally but not loaded correctly into hardware
Medical Devices Recalls
Medical equipment, implants, and diagnostic devices
The action is being initiated due to internal testing which identified a possibility for transducers to exceed the acoustic output power (AOP) values defined . The transit voltage values based on PW Doppler are calculated normally but not loaded correctly into hardware
MAGNETOM Skyra magnetic resonance diagnostic devices Model # 10432915
Siemens Medical Solutions USA
Potential of an open port in the quench venting system when using the optional horizontal outlet on the quench line assembly.
Kit BD Max CT/GC/TV; Catalog # 442970
Becton Dickinson &
The foil bags containing extraction tubes for BD MAX" Reagent products may not been sealed properly.
Outflow Graft leaking at the pump connection during the implantation process. If the C-Ring is insufficiently seated, it renders the device nonfunctional because the Outflow Graft connection will leak during the implant procedure.
Kit BD Max Cdiff EU; Catalog # 442555
Becton Dickinson &
The foil bags containing extraction tubes for BD MAX" Reagent products may not been sealed properly.
MAGNETOM Aera magnetic resonance diagnostic devices Model # 10432914
Siemens Medical Solutions USA
Potential of an open port in the quench venting system when using the optional horizontal outlet on the quench line assembly.
Luer Lock Set - Catalog # MPC-125, for IV administration sets.
Molded Products
Mislabeling - Some unit of sale packages (bags of 100 sets of MPC-125) were found to be incorrectly labeled as Molded Products Male to Male Luer Adapters, Catalog # MPC-150.
BD Vacutainer Lithium HeparinN 75 USP Units Blood Collection Tubes, Catalog Number 367884
Becton Dickinson & Company
False elevation of carboxyhemoglobin (COHb) results have been reported when using venous blood gas samples collected with tubes analyzed with the IL GEM 4000 instrument.
Edwards SAPIEN 3 Ultra Transcatheter Heart Valve System (SAPIEN 3 Ultra Delivery System) (26mm) 9630TF26 UDI:00690103201253
Edwards Lifesciences
The action has been initiated to address reports of burst balloons which have resulted in significant difficulty retrieving the device into the sheath and withdrawing the system from the patient during procedures
The anti-tip tubes potentially fail in certain situations and the wheelchairs can tip backwards.
ABL90 FLEX Analyzer REF 393090 UDI:05700693930909
Radiometer America
Software Security; The action is being initiated because of software security vulnerabilities with the firm's analyzer operating system, which may cause the device to shutdown or reboot resulting in delayed medical treatment.
Kit BD Max GC RT PCR Assay; Catalog # 443486
Becton Dickinson &
The foil bags containing extraction tubes for BD MAX" Reagent products may not been sealed properly.
BD Vacutainer LH (Lithium Heparin) 102 I.U. Plus Blood Collection Tubes, Catalog Number 368886
Becton Dickinson & Company
False elevation of carboxyhemoglobin (COHb) results have been reported when using venous blood gas samples collected with tubes analyzed with the IL GEM 4000 instrument.
BD Vacutainer PST Blood Collection Tubes, Catalog Number 368035, 368036
Becton Dickinson & Company
False elevation of carboxyhemoglobin (COHb) results have been reported when using venous blood gas samples collected with tubes analyzed with the IL GEM 4000 instrument.
Kit BD Max Enteric Parasite Panel EU; Catalog # 442960
Becton Dickinson &
The foil bags containing extraction tubes for BD MAX" Reagent products may not been sealed properly.
BD Vacutainer Lithium HeparinN (LH) 158 USP Units Blood Collection Tubes, Catalog Number 367880
Becton Dickinson & Company
False elevation of carboxyhemoglobin (COHb) results have been reported when using venous blood gas samples collected with tubes analyzed with the IL GEM 4000 instrument.
N Cuvette Segments for BN ProSpec System-IVD a system for the quantitative determination of proteins in serum, plasma, urine and CSF. Siemens Material Number (SMN):10446539
Siemens Healthcare Diagnostics
Iincreased (falsely elevated) Albumin results compared to expected results
Kit BD Max ExK DNA 2 USA; Catalog # 442819
Becton Dickinson &
The foil bags containing extraction tubes for BD MAX" Reagent products may not been sealed properly.
BD Vacutainer PST Gel and Lithium HeparinN (LH) Blood Collection Tubes, Catalog Number 367963
Becton Dickinson & Company
False elevation of carboxyhemoglobin (COHb) results have been reported when using venous blood gas samples collected with tubes analyzed with the IL GEM 4000 instrument.