πŸ₯

Medical Devices Recalls

Medical equipment, implants, and diagnostic devices

38,779 Total Recalls

There is a risk that blind screws of the modular tibial component cannot be loosened intraoperatively. This may lead to prolongation of surgery due to an intraoperative change in procedure.

May 24, 2022 Other Medical Devices View Details β†’

The Cathcart Ball has an inherent +5mm offset which is not currently specified in its Instructions for Use or Surgical Technique Guide. The STG has been updated to reflect the clarification that the +5mm offset should be taken into consideration when using a Cathcart head in a construct for hemi-hip arthroplasty procedures.

May 18, 2022 Implants & Prosthetics Nationwide View Details β†’
Class I - Dangerous

Due to battery cap deterioration, this may potentially result in an incomplete battery circuit (similar to when battery cap is not attached) and a loss of power/functionality of the insulin infusion pumps.

May 23, 2022 Infusion Pumps Nationwide View Details β†’
Class I - Dangerous

Following a system restart where the Table Height 2 (TH2) is the default setting and then switched to Wallstand VS2, operators will see an incorrect orientation of image on the first examination due to an issue in the firmware of the Wallstand VS2 board. The system will rotate the amplimat field selection by 90 degrees. The wrong amplimat field selection may cause an incorrect dose of radiation to occur. Additionally, the anatomic position markers may become mispositioned and could potentially be associated with the opposite side of the anatomy. (Updated 1/30/23) Expansion of the root cause to include incorrect amplimat field selection by 90 degrees following the first exposure using Wallstand VS2 and a subsequent system restart. Previously, this issue only occurred following a system restart where the Table Height 2 (TH2) is the default setting.

May 19, 2021 Other Medical Devices Nationwide View Details β†’
Class I - Dangerous

When starting a humidifier, intended for respiratory gas conditioning during invasive and noninvasive mechanical ventilation, with an empty chamber, and water is not filled into the chamber, the low water level alarm will be delayed and medical staff are unaware that there is no water in the chamber.

Jan 5, 2021 Other Medical Devices View Details β†’

SE primer may be missing some or all of the resin portion of the chemistry. The absence of resin may impact bond strength and restoration while using the primer.

Jun 1, 2022 Infusion Pumps Nationwide View Details β†’

The outer package is mislabeled and the package contains a different IOL strength.

May 13, 2022 Other Medical Devices Nationwide View Details β†’
Class I - Dangerous

There is the potential for the X-Ray system to short circuit due to an ingress of liquid in the display handles which may result in uncontrolled movement of the Overhead Tube Crane (OTC).

May 5, 2021 Other Medical Devices Nationwide View Details β†’

Positive bias with Lithium Heparin plasma samples from individuals that are expected to be below the 99th percentile of 0.07 ng/mL [0.07 ΒΏg/L], may lead to inappropriate intervention for myocardial infarction

May 18, 2022 Diagnostic Equipment Nationwide View Details β†’