Class I - Dangerous

During the "Load tip racks and enzymes" step of the run set-up, the info screen indicates "minimal volume to be loaded", but the indicated volume is instead the exact volume that should be loaded. Misunderstanding the guidance may lead to over diluted, under diluted, or improperly lysed sample, which in turn could lead to false negative or false positive results.

Nov 21, 2021 Other Medical Devices Nationwide View Details →

Specific GXL acetabular polyethylene liners, packaged in non-conforming bags, may adversely impact the device and contribute to accelerated wear.

Aug 11, 2022 Implants & Prosthetics Nationwide View Details →

GXL acetabular liners, orthopedic hip implant component. Product Line Numbers: a. ACUMATCH 0 DEGREE LINER 28MM 46MM, REF 130-28-05; b. ACUMATCH 0 DEGREE LINER 28MM 48MM, REF 130-28-06; c. ACUMATCH 0 DEGREE LINER 28MM 50/52MM, REF 130-28-07; d. ACUMATCH 0 DEGREE LINER 28MM 54/56MM, REF 130-28-08; e. ACUMATCH 0 DEGREE LINER 28MM 58/64MM, REF 130-28-09; f. ACUMATCH 15 DEGREE LINER 22MM SZ D, REF 132-22-04; g. ACUMATCH 15 DEGREE LINER 22MM SZ E, REF 132-22-05; h. ACUMATCH 15 DEGREE LINER 22MM SZ F, REF 132-22-06; i. ACUMATCH 15 DEGREE LINER 22MM SZ G, REF 132-22-07; j. ACUMATCH 15 DEGREE LINER 22MM SZ H, REF 132-22-08; k. ACUMATCH 15 DEGREE LINER 28MM SZ E, REF 132-28-05; l. ACUMATCH 15 DEGREE LINER 28MM SZ F, REF 132-28-06; m. ACUMATCH 15 DEGREE LINER 28MM SZ G, REF 132-28-07; n. ACUMATCH 15 DEGREE LINER 28MM SZ H, REF 132-28-08; o. ACUMATCH 15 DEGREE LINER 28MM SZ J, REF 132-28-09; p. ACUMATCH 15 DEGREE LINER 28MM SZ K, REF 132-28-10; q. ACUMATCH 15 DEGREE LINER 32MM SZ G, REF 132-32-07; r. ACUMATCH 15 DEGREE LINER 32MM SZ H, REF 132-32-08; s. ACUMATCH 15 DEGREE LINER 32MM SZ J, REF 132-32-09; t. ACUMATCH 15 DEGREE LINER 32MM SZ K, REF 132-32-10; u. ACUMATCH EXT COV LINER 28MM 46MM, REF 134-28-05; v. ACUMATCH EXT COV LINER 28MM 48MM, REF 134-28-06; w. ACUMATCH EXT COV LINER 28MM 50/52MM, REF 134-28-07; x. ACUMATCH EXT COV LINER 28MM 54/56MM, REF 134-28-08; y. ACUMATCH EXT COV LINER 28MM 58/64MM, REF 134-28-09; z. ACUMATCH EXT COV LINER 28MM 66/70MM, REF 134-28-10; aa. ACUMATCH LAT LINER 28MM 46MM, REF 138-28-05; bb. ACUMATCH LAT LINER 28MM 48MM, REF 138-28-06; cc. ACUMATCH LAT LINER 28MM 50/52MM, REF 138-28-07; dd. ACUMATCH LAT LINER 28MM 54/56MM, REF 138-28-08; ee. ACUMATCH LAT LINER 28MM 58/64MM, REF 138-28-09; ff. ACUMATCH 15 DEG LINER, SZ F, 28MM ID, REF CSK-1663; gg. ACUMATCH 15 DEG LINER, SZ G, 28MM ID, REF CSK-1664; hh. ACUMATCH 15 DEG LINER, SZ H, 28MM ID, REF CSK-1665

Exactech

Class I - Dangerous

Specific GXL acetabular polyethylene liners, packaged in non-conforming bags, may adversely impact the device and contribute to accelerated wear.

Aug 11, 2022 Implants & Prosthetics Nationwide View Details →

Surpria: Software Version V3.11, V3.22

FUJIFILM Healthcare Americas

Class I - Dangerous

Error 00003050 or 00003052 may occur during scanning, the captured images will not be reconstructed and the Raw Data will not be displayed in the work list.result, may result in the need for additional scanning to capture the images properly for reconstruction, thereby exposing the patient to additional radiation

Jul 12, 2022 Other Medical Devices Nationwide View Details →

The INOmax DSIR Delivery System, manufactured by Mallinckrodt Pharmaceuticals, is not compatible with the upgraded version of the Leoni Plus ventilator, manufactured by Lowenstein Medical. The Leoni Plus ventilator was recently upgraded in 2021 by Lowenstein Medical, with new hardware and software, and the upgraded version cannot be appropriately connected with the INOmax DSIR as instructed in the INOmax DSIR Operators Manual (OM). The INOmax DSIR OM requires the use of a one-way valve with the Leoni Plus ventilator during High Frequency Oscillatory Ventilation mode and warns that use of the device without a one-way valve may result in high Nitric Oxide (NO) delivery.

Jun 23, 2022 Infusion Pumps View Details →

Specific GXL acetabular polyethylene liners, packaged in non-conforming bags, may adversely impact the device and contribute to accelerated wear.

Aug 11, 2022 Implants & Prosthetics Nationwide View Details →

Product Description/Item: ChemoLock Bag Spike, 10 units/CL-10-10; ChemoLock BAG SPIKE w/ ADDITIVE PORT, DRY SPIKE/CL-12; APPX 1.5ml,ChemoLock BAG SPIKE WITH ADDITIVE PORT/CL-13; ChemoLock Port/CL2100; ChemoLock Port, 5 Units/CL2100-5; ChemoLock Port/CL2100T; Clave Bag Spike w ChemoLock Port/CL2150; 30" (76 cm) Appx 3.3 ml, 20 Drop Admin Set w Integrated ChemoLock Drip Chamber, Spiros w/Red Cap, Hanger/CL3011; 9 IN(23cm)APPX 2.7ml,EXT SET,ChemoLock PORT,2 CLAMPS,2 GRADUATED CONN/CL3364; Syringe Transfer Set w Clave, ChemoLock Port/CL-34; 30" (76 cm) Appx 3.6 ml, 20 Drop Admin Set w Integrated ChemoLock Port Drip Chamber, ChemoLock w Red Cap, Bag Hanger/CL3511; 30" (76 cm) Appx 3.6 ml, 20 Drop Admin Set w Integrated ChemoLock Port Drip Chamber, ChemoLock w Red Cap, Bag Hanger/CL3511T; 30" (76cm) Appx 6.3 ml, 20 Drop Admin Set w Integrated ChemoLock Port Drip Chamber, 0.2 Micron Filter, ChemoLock w Red Cap, Hanger/CL3528; 7" (18 cm) Appx .93 ml, Ext Set w/ChemoLock, Y-Connector, Rotating Luer/CL3535T; Oncology Kit w/5" (13 cm) Add-On Set w ChemoLock Additive Port, Vented Cap, ChemoLock, Spinning Spiros w Red Cap/CL3538; Graduated Connector w ChemoLock Port/CL3900; ONCOLOGY KIT, EXT,ChemoLock PORT, GRAD CONN,TRANSFER,ChemoLock,VIAL SPIKE,ChemoLock PORT/CL3927; Oncology Kit w 5" (13 cm) Add-On Set w ChemoLock w Red Cap, Vented Cap, ChemoLock Port w Bag Spike, Spiros w Red Cap/CL3946; Oncology Kit w 17" (43 cm) Bifuse Ext Set w/ChemoLock w Red Cap, ChemoLock Port, ChemoLock Vented Vial Spike, 13mm ChemoLock/CL3947; Oncology Kit w ChemoLock Port Closed Vial Spike, ChemoLock, ChemoLock Port Bag Spike/CL3952; APPX 0.5ml, ChemoLock BAG SPIKE WITH ADDITIVE PORT,ChemoLock Port/CL3955;

ICU Medical

Class I - Dangerous

Ports have a potential for unintended disconnection, inability to connect to or fully engage with injectors, due to a variation in the spring inside the Port, which may cause delay of therapy and exposure to caustic substances. Ports available as standalone connectors, or utilized as access points on vial adaptors, bag spikes, and administration sets.

Jun 27, 2022 Surgical Instruments Nationwide View Details →