Medical Devices Recalls

Medical equipment, implants, and diagnostic devices

38,779 Total Recalls

Inadvertent energy delivery from surgical system instrument if 1) Force bipolar and bipolar instruments installed on system 2) Force bipolar connected to Force Triad generator, bipolar not connected to generator 3) Yellow pedal associated with force bipolar is pressed, released with head in surgeon console 4) Blue pedal associated with bipolar is pressed, resulting in force bipolar energy delivery

Sep 20, 2022 Other Medical Devices Nationwide View Details →
Class I - Dangerous

Adult Blood Culture Collect kit and Pre-Op Changing Bathing Kit contain an incorrect expiration date on a component with the kit. CHG Solution with the Pre-Op Changing Bathing Kit and Bactec bottle plastic both have an expiration date that does not match the date listed on the kit.

Sep 9, 2022 Other Medical Devices Nationwide View Details →

Biopsy Systems have components that are misaligned due to an issue with the manufacturing assembly equipment, which may lead to the needle ejecting when triggered outside the body, which may result in user or patient needle stick injury.

Aug 3, 2022 Other Medical Devices Nationwide View Details →

Printed Instructions for Use (IFU) not shipped with device. The Instructions for Use contain the Warnings, Precautions, Contraindications, and Procedures for the Preparation, Implantation, and Post Operative Care of the implantable port, failure to follow the Instructions for Use may result in patient injury.

Sep 20, 2022 Implants & Prosthetics Nationwide View Details →

Assigned vial lot numbers for the incorrect type of product. SARS-CoV-2 & Flu A/B lot numbers were incorrectly assigned to the positive and negative vial lot numbers for SARS-CoV-2 Ag LQCs within batch 2002204017, which should have been assigned SARS-CoV-2 Ag lot numbers resulting in an error message and preventing use of the LQC

Sep 23, 2022 Diagnostic Equipment Nationwide View Details →
Class I - Dangerous

Adult Blood Culture Collect kit and Pre-Op Changing Bathing Kit contain an incorrect expiration date on a component with the kit. CHG Solution with the Pre-Op Changing Bathing Kit and Bactec bottle plastic both have an expiration date that does not match the date listed on the kit.

Sep 9, 2022 Other Medical Devices Nationwide View Details →

Biopsy Systems have components that are misaligned due to an issue with the manufacturing assembly equipment, which may lead to the needle ejecting when triggered outside the body, which may result in user or patient needle stick injury.

Aug 3, 2022 Other Medical Devices Nationwide View Details →

MEDLINE PRE-OP CHG BATHING KIT Reorder #: P164756

MEDLINE INDUSTRIES, LP - Northfield

Class I - Dangerous

Adult Blood Culture Collect kit and Pre-Op Changing Bathing Kit contain an incorrect expiration date on a component with the kit. CHG Solution with the Pre-Op Changing Bathing Kit and Bactec bottle plastic both have an expiration date that does not match the date listed on the kit.

Sep 9, 2022 Other Medical Devices Nationwide View Details →