Sterile custom surgical procedure packs: (1) 89-10507.02, TOTAL KNEE PACK, Stonewall Jackson Hospital; (2) 89-10508.02, LOCAL PACK, Stonewall Jackson Hospital; (3) 89-10509.02, LAPAROTOMY PACK, Stonewall Jackson Hospital; (4) 89-10517.04, CNRV BASIC SETUP PACK, New River Valley Medical Center; (5) 89-10526.04, CNRV LAPAROSCOPY PACK, New River Valley Medical Center; (6) 89-10530.04, CNRV PERIPHERAL VAS PACK, New River Valley Medical Center; (7) 89-10532.04, CNRV SPINE PACK, New River Valley Medical Center; (8) 89-10534.02, CMC ANTERIOR SPINE PACK, Carilion Roanoke Memorial Hosp; (9) 89-10544.03, CORONARY BYPASS PACK PGYBK, Carilion Roanoke Memorial Hosp; (10) 89-10545.02, CMC CRANIOTOMY PACK, Carilion Roanoke Memorial Hospital; (11) 89-10552.02, CMC EXTREMITY PACK, Carilion Roanoke Memorial Hospital; (12) 89-10553.02, CMC GYN LAPAROSCOPY PACK, Carilion Roanoke Memorial Hospital; (13) 89-10554.02, CMC GYN MAJOR PACK, Carilion Roanoke Memorial Hospital; (14) 89-10555.02, ORTHO MAJOR PACK, Carilion Roanoke Memorial Hospital; (15) 89-10556.02, CMC HYSTEROSCOPY PACK, Carilion Roanoke Memorial Hospital; (16) 89-10558.04, CCASC LAPAROTOMY PACK, Carilion Roanoke Memorial Hospital; (17) 89-10560.03, CMC LAPAROTOMY PACK, Carilion Roanoke Memorial Hospital; (18) 89-10561.02, CMC LAPAROSCOPY PACK, Carilion Roanoke Memorial Hospital; (19) 89-10562.02, CMC MINOR ENT/PLASTIC PACK, Carilion Roanoke Memorial Hospital; (20) 89-10564.02, CMC MAJOR PLASTIC PACK, Carilion Roanoke Memorial Hospital; (21) 89-10569.02, CMC PEDIATRIC PACK, Carilion Roanoke Memorial Hospital; (22) 89-10570.02, CMC POSTERIOR SPINE PACK, Carilion Roanoke Memorial Hospital; (23) 89-10574.02, CMC SHOULDER ARTHROSCOPY PACK, Carilion Roanoke Memorial Hospital; (24) 89-10575.02, OWEN HIP PACK, Carilion Roanoke Memorial Hosp; (25) 89-10576.03, THORACOSCOPY / THORACOTOMY, Carilion Roanoke Memorial Hosp; (26) 89-10580.03, VALVE REPLACEMENT PACK PGYBK, Carilion Roanoke Memorial Hosp.

DeRoyal Industries

Class I - Dangerous

The custom procedure packs contain light handle covers that have been recalled by another firm.

Apr 17, 2023 Implants & Prosthetics Nationwide View Details β†’

In nonaxial/some axial exams if surgical plan utilized, Target Guidance selected, tip projection utilized, Navigate Projection enabled, software anomaly may occur during tumor resection/shunt placement/deep brain stimulation, where distance to/past target text no longer synchronized with navigation information, inaccurate value displayed; may result in prolonged/additional procedure, tissue injury

Apr 11, 2023 Other Medical Devices View Details β†’

SPM software anomalies that may lead to the generation of erroneous 4Kscore Test results

Nov 18, 2022 Diagnostic Equipment Nationwide View Details β†’
Class I - Dangerous

The Trilogy Evo Universal ventilator provides continuous or intermittent positive pressure ventilation for the care of individuals who require mechanical ventilation. Trilogy Evo Universal is intended for pediatric through adult patients weighing at least 2.5 kg. The ventilator can measure, display, record, and alarm SpO2, FiO2, CO2, and pulse rate data when integrated with the appropriate accessories. The ventilator is suitable for use in institutional and hospital settings and non-emergency transport settings; for example, wheelchair. It may be used for both invasive and non-invasive ventilation.

May 1, 2023 Patient Monitors Nationwide View Details β†’

IFU Warning: Applying bending force and/or bending force with impaction to the BIOKNOTLESSΒΏ Anchor Inserter may cause a fragment of the inserter tip to break off during use and be retained in the patient. broken BIOKNOTLESSΒΏ Anchor inserter tip detected during surgery may require removal, potentially causing bone damage and longer surgery time

Apr 13, 2023 Infusion Pumps Nationwide View Details β†’

Some catheters had a manufacturing defect where the clear resealing label separating from the product foil pouch, resulting in a possible opening into the product packaging that could impact product sterility.

Apr 20, 2023 Surgical Instruments View Details β†’

Environmental debris may accumulate on the internal machine flow sensor causing partial occlusion which may impact accurate delivery of pressure, volume, or flow. A malfunction caused by this issue can result in patient harm up to hypoxemia if not addressed by the care provider.

May 1, 2023 Other Medical Devices Nationwide View Details β†’

Potential Loss of X-ray-When the full disk capacity is reached, X-Ray functionality will cease to be available there will be a sudden interruption of the procedure

Mar 21, 2023 Other Medical Devices Nationwide View Details β†’

Product packaging may exhibit small pinholes which may not be visible to the unaided eye, compromising the sterile barrier of the packaging. Exposure to non-sterile device may result in inflammation, infection, sepsis, and ischemia.

May 18, 2023 Other Medical Devices Nationwide View Details β†’