Firm has received complaints from patients who are unable to exit MRI (Magnetic Resonance Imaging) mode on their IPGs (Implantable Pulse Generators).

Jul 18, 2023 Implants & Prosthetics Nationwide View Details →

LANDAUER received reports indicating that some nanoDots may potentially be outside of the specified range of +/-5.5% accuracy. Investigation of nanoDots indicated the presence of a potential non-conformance in the Optical Stimulated Luminescence (OSL) material that is beamed after exposure and emits fluorescence proportional to radiation exposure.

Jul 12, 2023 Diagnostic Equipment View Details →

LANDAUER received reports indicating that some nanoDots may potentially be outside of the specified range of +/-5.5% accuracy. Investigation of nanoDots indicated the presence of a potential non-conformance in the Optical Stimulated Luminescence (OSL) material that is beamed after exposure and emits fluorescence proportional to radiation exposure.

Jul 12, 2023 Diagnostic Equipment View Details →

Allura Xper series

Philips Medical Systems Nederland B.V.

Class I - Dangerous

A foot switch pedal may get stuck in the active position when the user releases the pedal, resulting in the emission of unintended radiation

Jul 19, 2023 Other Medical Devices Nationwide View Details →

Azurion

Philips Medical Systems Nederland B.V.

Class I - Dangerous

A foot switch pedal may get stuck in the active position when the user releases the pedal, resulting in the emission of unintended radiation

Jul 19, 2023 Other Medical Devices Nationwide View Details →

Transducer, an ultrasound system accessory, consists of two parts that are bonded together that may come apart due to chassis bonding issue, which may pose risk to users and patients of tissue damage, and electric shock if the built-in safety measures to prevent electric were to also fail.

Jun 30, 2023 Other Medical Devices Nationwide View Details →

The Distal Attachment contain di-2-ethylhexyl phthalate (DEHP), which exceeds the permissible exposure level calculated according to ISO 10993-17: 2002

Jul 27, 2023 Other Medical Devices Nationwide View Details →

MultiDiagnost-Eleva

Philips Medical Systems Nederland B.V.

Class I - Dangerous

A foot switch pedal may get stuck in the active position when the user releases the pedal, resulting in the emission of unintended radiation

Jul 19, 2023 Other Medical Devices Nationwide View Details →

Users were reporting that the device was not charging as expected. It was discovered that users were unaware that the Cardiosave console was not completely inserted into the hospital cart. If the console is not fully inserted back into the cart the battery(ies) will not charge.

Jul 31, 2023 Infusion Pumps Nationwide View Details →

Epoxy used during manufacturing of the LifeSPARC Pump may have uncured epoxy. if undetectable curing may result in added risk of early pump failure,

Jun 30, 2023 Infusion Pumps Nationwide View Details →

Users were reporting instances of "Gas Loss in IAB Circuit" and "Gas Gain in IAB Circuit" alarms while providing therapy. An internal investigation of the complaints determined that there is a potential trigger for these alarms that was not listed in the IFU: Patient Movement (coughing, general movement, and swallowing). Blood in the circuit, kins and abrasions of the tubing/catheter and certain patient conditions could also trigger these alarms. The HHE also identified hardware issues related to these alarms.

Jul 31, 2023 Infusion Pumps Nationwide View Details →