VITROS Immunodiagnostic Products Troponin I ES Calibrators
ORTHO-CLINICAL DIAGNOSTICS
Reagent packs could potentially contain incorrect wells, which will generate incorrect, and potentially false negative, results.
Medical equipment, implants, and diagnostic devices
ORTHO-CLINICAL DIAGNOSTICS
Reagent packs could potentially contain incorrect wells, which will generate incorrect, and potentially false negative, results.
Stryker Sustainability Solutions
39-inche-wide inflatable air transfer mattress packages contain 34-Inch-wide mattresses, so there may be a decreased surface area available to distribute the patient's weight across, which may increase the effort exerted by staff for a lateral patient transfer, and there may be increased friction and shearing forces when the patient is moved resulting in skin tear injury.
Johnson & Johnson Surgical Vision
Weld protrusion/physical gap between the housing and pack cover, may exceed design specification, due to a manufacturing issue, which could lead to priming cycle failure and/or suboptimal vacuum delivered to the phacoemulsification and irrigation/aspiration handpieces during surgery, which could result in surgical delay and/or longer surgical time, which could result in transient corneal edema.
Thread form issue of the locking holes in that the locking screws would not properly mate with the plate. The improperly mated screw may not be readily recognizable by the user since the screw may not correctly lock.
PHILIPS MEDICAL SYSTEMS NEDERLAND B.V.
The bolts supporting the FlexMove Carriage may become loose and/or break, and cracks may appear in the suspension rail of the FlexMove Carriage.
Wrong versions of guides 3A and 3B (Patient Specific) were shipped prior to the re-design request
Siemens Medical Solutions USA
During a whole-body planar scan with auto-contour, there is a possibility the short-linear drive (SLD) look-ahead sensors may trigger earlier than expected and may result in detector 1 positioning further from the patient than needed leading to a reduction in image resolution.
Olympus Corporation of the Americas
Electromagnetic (EM) sensor tracking malfunction impacts the use of navigation functionality during endobronchial procedures and prompts the system to report a coil break warning message. This could result in a potential procedural delay
Potential for the labeled sterile ultrasound gel component within packs to not meet sterility specifications.
The STATCLAVE G4 is a dynamic air removal (prevacuum) tabletop steam sterilizer intended for use by a health care provider to sterilize medical products by means of pressurized steam. It is suitable for the sterilization of dental and medical instruments that are validated to be sterilized by steam. The STATCLAVE G4 has not been designed to sterilize liquid loads, bio medical waste or materials not compatible with steam sterilization. The processing of such loads may result in incomplete sterilization and / or damage to the autoclave.
MEDLINE INDUSTRIES, LP - Northfield
Potential for the labeled sterile ultrasound gel component within packs to not meet sterility specifications.
Potential for the labeled sterile ultrasound gel component within packs to not meet sterility specifications.
Non-conforming product may appear in the field as inability to advance or retract the basket, or the drive wire breaking or separating from handle (with or without mechanical lithotripsy).
MEDLINE INDUSTRIES, LP - Northfield
Potential for the labeled sterile ultrasound gel component within packs to not meet sterility specifications.
Potential for the labeled sterile ultrasound gel component within packs to not meet sterility specifications.
SHIMADZU CORPORATION MEDICAL SYSTEMS DIVISION
Eight fixing bolts at the base of the X-ray ceiling tube column assembly may be loose or missing so service is required to install a cable, bracket, and label behind the bracket, indicating when service is required, to eliminate the risk of the device falling.
Olympus Corporation of the Americas
Electromagnetic (EM) sensor tracking malfunction impacts the use of navigation functionality during endobronchial procedures and prompts the system to report a coil break warning message. This could result in a potential procedural delay
Certain lots of the products have a Naphthalene odor.
Olympus Corporation of the Americas
Electromagnetic (EM) sensor tracking malfunction impacts the use of navigation functionality during endobronchial procedures and prompts the system to report a coil break warning message. This could result in a potential procedural delay
Creganna Medical Devices
Three lots of product may be labeled with an incorrect expiration day