Medical Devices Recalls
Medical equipment, implants, and diagnostic devices
RayStation 9.0.0.113 and 9.0.1.142. Radiation Therapy Treatment Planning System.
RAYSEARCH LABORATORIES AB
Potential for reported SSD to be too high.
Jackson-Pratt 3-Spring Reservoir Kit with PVC Round Drain, 400mL, 10Fr., REF SU130-402D
Cardinal Health 200
Cardinal Health is issuing a lot number specific voluntary removal of Jackson-Pratt 3-Spring Reservoir kits due to specific products being shipped to users before undergoing sterilization.
Due to a misaligned calibration of the wired controller that may result in unintended motion of the scope.
Thread form issue for the locking holes in that the locking screws may not properly mate with the plate. The improperly mated screw may not be readily recognizable by the user since the screw may not correctly lock, may result in delay in surgery or loss of fixation resulting further intervention
Thread form issue for the locking holes in that the locking screws may not properly mate with the plate. The improperly mated screw may not be readily recognizable by the user since the screw may not correctly lock, may result in delay in surgery or loss of fixation resulting further intervention
Thread form issue for the locking holes in that the locking screws may not properly mate with the plate. The improperly mated screw may not be readily recognizable by the user since the screw may not correctly lock, may result in delay in surgery or loss of fixation resulting further intervention
RayStation 11.0.0.951, 11.0.1.29, 11.0.3.116 & 11.0.4.15. Radiation Therapy Treatment Planning System.
RAYSEARCH LABORATORIES AB
Potential for reported SSD to be too high.
Thread form issue for the locking holes in that the locking screws may not properly mate with the plate. The improperly mated screw may not be readily recognizable by the user since the screw may not correctly lock, may result in delay in surgery or loss of fixation resulting further intervention
Thread form issue for the locking holes in that the locking screws may not properly mate with the plate. The improperly mated screw may not be readily recognizable by the user since the screw may not correctly lock, may result in delay in surgery or loss of fixation resulting further intervention
RayStation 8.0.0.61, 8.0.1.10. Radiation Therapy Treatment Planning System.
RAYSEARCH LABORATORIES AB
Potential for reported SSD to be too high.
Jackson-Pratt 3-Spring Reservoir with Silicone Adapters, 400mL, REF SU130-475
Cardinal Health 200
Cardinal Health is issuing a lot number specific voluntary removal of Jackson-Pratt 3-Spring Reservoir kits due to specific products being shipped to users before undergoing sterilization.
IPS e.max ZirCAD CER/in. Prime A3 C17/5 -A zirconium oxide block for the fabrication of fixed, full-contour restorations in anterior and posterior teeth Article Number: 758439
IVOCLAR VIVADENT AG
Defective blocks may show cracks after sintering If cracks are unnoticed, restorations may fracture in the patient's mouth and require restoration
System error messages may delay the ability to test patient samples and the need for frequent calibration due to results outside the expected range when testing controls.
The Oncology Essentials Package of the Spectral CT imaging system.
Philips North America
Potential for third party oncology marking laser to be reflected off the gantry cover surface, which can potentially lead to misdiagnosis and subsequent incorrect treatment.
Thread form issue for the locking holes in that the locking screws may not properly mate with the plate. The improperly mated screw may not be readily recognizable by the user since the screw may not correctly lock, may result in delay in surgery or loss of fixation resulting further intervention
Thread form issue for the locking holes in that the locking screws may not properly mate with the plate. The improperly mated screw may not be readily recognizable by the user since the screw may not correctly lock, may result in delay in surgery or loss of fixation resulting further intervention
Thread form issue for the locking holes in that the locking screws may not properly mate with the plate. The improperly mated screw may not be readily recognizable by the user since the screw may not correctly lock, may result in delay in surgery or loss of fixation resulting further intervention
RayStation 15.0.0.430. Radiation Therapy Treatment Planning System.
RAYSEARCH LABORATORIES AB
Potential for reported SSD to be too high.
Stryker Neurovascular is recalling their DAC- Distal Access Catheter -038 136cm, a Distal Access Catheter by removal. The reason for the recall is: the DAC Lot #0000486382 was released with out-of-specification endotoxin results.