Metasul¿ Head. Intended for use either with or without bone cement in total hip arthroplasty.
Zimmer
The low density polyethylene (LDPE) bag used to package implants adheres to the highly polished surface of the devices.
Medical equipment, implants, and diagnostic devices
Zimmer
The low density polyethylene (LDPE) bag used to package implants adheres to the highly polished surface of the devices.
The sterility of this product to a Sterility Assurance Level (SAL) of 10(-6) cannot be assured.
The low density polyethylene (LDPE) bag used to package implants adheres to the highly polished surface of the devices.
Xoran Technologies
A description of the defect in the product or the manner in which the product fails to comply wvith an applicable Federal standard; The MiniCAT CT Scanners subject to this notification failed to meet Xoran's specifications for dose rate of 125 ¿ 3 kVp. These 18 complaints received include dose rates both on the high and low end of Xoran's specifications. See ATTACHMENT 1 for details. (e) A n evalu
Dilators and Holding Clip are being used for a secondary function of neuromonitoring, for which it is not 510(k) cleared.
GE has recently become aware of potential issues due to out of context issues associated with specific workflows of the Centricity PACS RA1000 workstation. These issues are as follows: 1) In Centricity RIS-IC, and a RIS-Driven integration, the "close" button closes the exam in RIS-IC, but does not close the exam in Centricity PACS RA1000 Workstation. 2) Interrupted workflow could break the
Dilators and Holding Clip are being used for a secondary function of neuromonitoring, for which it is not 510(k) cleared.
It was discovered that the silicone potting failed to properly cure after undergoing the prescribed curing possess. The potting material is used to insulate, stabilize and provide a moisture barrier to the TPS MicroDriver main Printed Circuit Board Assembly (PCBA). Inadequate cure of the silicone potting could potentially allow it to leak to the outside of the handpiece or cause an electrical ma
Integra LifeSciences has identified through an internal evaluation that in order to comply with US FDA requirements, certain Camino¿ Intracranial Pressure Monitoring Kits require additional labelling to indicate they are UNSAFE in an MR environment. Only the following Camino¿ Intracranial Pressure Monitoring Kits are affected: 110-4B, 110-4BC, 110-4G, 110-4H, 110-4HC, 110-4L, 110-4LC.
The low density polyethylene (LDPE) bag used to package implants adheres to the highly polished surface of the devices.
Xoran Technologies
The MiniCAT CT Scanners subject to this notification failed to meet Xoran's specifications for dose rate of 125 ¿ 3 kVp. These 18 complaints received include dose rates both on the high and low end of Xorans specifications.
Complaints for Salmonella strains growing on this medium producing an uncharacteristic white colored colony instead of the expected pale pink to mauve colored colonies. This could potentially lead to Salmonella colonies not being detected.
The low density polyethylene (LDPE) bag used to package implants adheres to the highly polished surface of the devices.
Improper restraints during transportation of the da Vinci system could cause the HRSV Monitor to become loose from its mount.
Edwards Lifesciences is recalling certain lots of EMBOL-X Glide Protection System due to deformation of the cannula tip.
The recall was initiated due to an increased risk of implants breaching the sterile pouches inside the shrink-wrapped box.
Philips received reports from the field that the Flat Panel Detector (FPD) does not always remain securely latched in the stowed position.
HemoCue AB has become aware of a production related problem involving punctured HemoCue Hb 201 Microcuvettes single pack pouches.
The low density polyethylene (LDPE) bag used to package implants adheres to the highly polished surface of the devices.
The low density polyethylene (LDPE) bag used to package implants adheres to the highly polished surface of the devices.