A potential issue with false high values.
Medical Devices Recalls
Medical equipment, implants, and diagnostic devices
Product sold after April 1, 2014 were inadvertently filled with hydrogen peroxide teeth whitening gel (6% concentration as dispensed) on one side of the dual barrel syringe instead of the intended component (phosphate gel). Consequently, use of this product by patients may result in a neutral effect or increased sensitivity.
8MM, TIP-UP FENESTRATED GRASPER; Intended to assist in the accurate control of Intuitive Surgical Endoscopic Instruments.
Intuitive Surgical
Deviations in reprocessing steps from those stated in the reprocessing instructions can cause surface degradation of the housing and/or accelerate mechanical wear of the instrument.
Some patients are obtaining access to the dosage reset codes required to change the settings on GemStar infusion pumps and are subsequently changing the infusion rate set by their doctors. Patients are obtaining access to these codes via website sponsors by downloading the GemStar User/Service Manual featured on the sponsors' websites. The GemStar User/Service Manual should be removed from these w
8MM, TENACULUM FORCEPS; Intended to assist in the accurate control of Intuitive Surgical Endoscopic Instruments.
Intuitive Surgical
Deviations in reprocessing steps from those stated in the reprocessing instructions can cause surface degradation of the housing and/or accelerate mechanical wear of the instrument.
8MM MONOPOLAR CURVED SCISSORS; Intended to assist in the accurate control of Intuitive Surgical Endoscopic Instruments.
Intuitive Surgical
Deviations in reprocessing steps from those stated in the reprocessing instructions can cause surface degradation of the housing and/or accelerate mechanical wear of the instrument.
8MM, MEGA SUTURECUT ND; Intended to assist in the accurate control of Intuitive Surgical Endoscopic Instruments.
Intuitive Surgical
Deviations in reprocessing steps from those stated in the reprocessing instructions can cause surface degradation of the housing and/or accelerate mechanical wear of the instrument.
8MM,MARYLAND BIPOLAR FORCEPS; Intended to assist in the accurate control of Intuitive Surgical Endoscopic Instruments.
Intuitive Surgical
Deviations in reprocessing steps from those stated in the reprocessing instructions can cause surface degradation of the housing and/or accelerate mechanical wear of the instrument.
The product may appear cloudy or discolored and may not perform correctly in presumptive diagnosis of mycobacterial disease.
Some patients are obtaining access to the dosage reset codes required to change the settings on GemStar infusion pumps and are subsequently changing the infusion rate set by their doctors. Patients are obtaining access to these codes via website sponsors by downloading the GemStar User/Service Manual featured on the sponsors' websites. The GemStar User/Service Manual should be removed from these w
8MM, DUAL BLADE RETRACTOR; Intended to assist in the accurate control of Intuitive Surgical Endoscopic Instruments.
Intuitive Surgical
Deviations in reprocessing steps from those stated in the reprocessing instructions can cause surface degradation of the housing and/or accelerate mechanical wear of the instrument.
A reagent within the test may return false negative results.
8MM,MEDIUM-LARGE CLIP APPLIER ; Intended to assist in the accurate control of Intuitive Surgical Endoscopic Instruments.
Intuitive Surgical
Deviations in reprocessing steps from those stated in the reprocessing instructions can cause surface degradation of the housing and/or accelerate mechanical wear of the instrument.
Abbott m2000sp, an automated system for performing sample preparation for nucleic acid testing.
Abbott Molecular
Some versions of Application Specifications (App Spec) are incompatible with m2000sp system software version 6.0 and 7.0. This issue will cause Error Code 9000 (An unexpected error has occurred: Software error) to be generated when the Available Reagent Packs screen is selected.
Cannulaide recalled May 2008 due to improper seal of the pouch. The improper seal of the Cannulaide's package could potentially affect the device shelf life.
8MM, CURVED BIPOLAR DISSECTOR; Intended to assist in the accurate control of Intuitive Surgical Endoscopic Instruments.
Intuitive Surgical
Deviations in reprocessing steps from those stated in the reprocessing instructions can cause surface degradation of the housing and/or accelerate mechanical wear of the instrument.
Dharma Cavity Varnish 15mL
Dharma Research
During an FDA inspection it was found that the products are marketed without a cleared 510k.
17% of ARCHITECT Total T3 Reagent Kit, LN 7K64-20/-25 reagent lots 38901UI00 and 38901UI01 may exhibit lower Relative Light Units (RLUs) than expected, which in turn may result in controls out of range or patient results higher than expected.
The welds on J700 tube stands may be insufficient resulting in tube stand breakage, damage to the X-Ray machine, and/or patient or healthcare provider injury.
Potential problem with the cardiac function analysis software (CFA). Incorrect analysis results may be displayed in the Function Parameters for the Entire Heart displayed as analysis results of the CFA and in a Left-Ventricular Volume Curve generated based on some of those parameters.